Randomized Controlled Trials of Artificial Intelligence in Clinical Practice: Systematic Review

Randomized Controlled Trials of Artificial Intelligence in Clinical Practice: Systematic Review

Randomized Controlled Trials of Artificial Intelligence in Clinical Practice: Systematic Review

Review

1The Jockey Club School of Public Health and Primary Care, The Chinese University of Hong Kong, Hong Kong, Hong Kong

2Stanley Ho Big Data Decision Analytics Research Centre, The Chinese University of Hong Kong., Hong Kong, Hong Kong

3Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore

4Department of Medicine (Digestive Diseases), Yale School of Medicine, New Haven, CT, United States

*these authors contributed equally

Corresponding Author:

Joseph J Y Sung, MD, PhD

Lee Kong Chian School of Medicine

Nanyang Technological University

Lee Kong Chian School of Medicine, Nanyang Technological University

11 Mandalay Road

Singapore, 308232

Singapore

Phone: 65 65138886

Fax:65 63392889

Email: josephsung@ntu.edu.sg


Background: The number of artificial intelligence (AI) studies in medicine has exponentially increased recently. However, there is no clear quantification of the clinical benefits of implementing AI-assisted tools in patient care.

Objective: This study aims to systematically review all published randomized controlled trials (RCTs) of AI-assisted tools to characterize their performance in clinical practice.

Methods: CINAHL, Cochrane Central, Embase, MEDLINE, and PubMed were searched to identify relevant RCTs published up to July 2021 and comparing the performance of AI-assisted tools with conventional clinical management without AI assistance. We evaluated the primary end points of each study to determine their clinical relevance. This systematic review was conducted following the updated PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 guidelines.

Results: Among the 11,839 articles retrieved, only 39 (0.33%) RCTs were included. These RCTs were conducted in an approximately equal distribution from North America, Europe, and Asia. AI-assisted tools were implemented in 13 different clinical specialties. Most RCTs were published in the field of gastroenterology, with 15 studies on AI-assisted endoscopy. Most RCTs studied biosignal-based AI-assisted tools, and a minority of RCTs studied AI-assisted tools drawn from clinical data. In 77% (30/39) of the RCTs, AI-assisted interventions outperformed usual clinical care, and clinically relevant outcomes improved with AI-assisted intervention in 70% (21/30) of the studies. Small sample size and single-center design limited the generalizability of these studies.

Conclusions: There is growing evidence supporting the implementation of AI-assisted tools in daily clinical practice; however, the number of available RCTs is limited and heterogeneous. More RCTs of AI-assisted tools integrated into clinical practice are needed to advance the role of AI in medicine.

Trial Registration: PROSPERO CRD42021286539; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=286539

J Med Internet Res 2022;24(8):e37188

doi:10.2196/37188

Keywords



Background

Artificial intelligence (AI) was first described in the 1950s as a theory of human intelligence being exhibited by machines, including but not limited to learning, reasoning, and problem-solving [1]. With an exponential increase of computational power, reduced cost of data storage, improved algorithmic sophistication, and increased availability of health data from electronic health records, the era of AI has arrived in different specialties of medicine [2-4]. AI-assisted tools have been successfully applied in various clinical settings to assist diagnosis [5], improve therapy [6], and predict risk of mortality [7]. To date, 64 AI-powered medical devices and algorithms have been approved by the Food and Drug Administration in the United States [8].

The number of AI-related articles (using the Medical Subject Headings term, “artificial intelligence” as the search keyword) in the health care literature has increased dramatically from 6802 articles in 2016 to 21,160 in 2020. However, only a minority of these are prospective clinical studies, and there are few randomized controlled trials (RCTs). Several systematic reviews have been conducted to summarize the performance of recent AI-assisted tools in specific clinical settings, such as AI-assisted adenoma detection during colonoscopy [9], AI-assisted mammography in detecting breast cancer [10], AI-assisted intracranial hemorrhage recognition on computed tomography head imaging [11], AI-assisted glycemic control for patients with diabetes, and AI-assisted diagnosis of diabetes and its related complications [12]. A recent systematic review examined all studies of AI application in clinical practice, but was limited by restriction to English language and only searching full manuscripts published between January 2010 and May 2020 [13].

Objectives

To date, no systematic review has been restricted to RCTs regarding the clinical performance of AI-assisted tools in real-life practice. As RCTs represent the best clinical evidence to examine the effects of an intervention while controlling for unmeasured confounding factors, a comprehensive search of all RCTs studying AI-assisted tools in clinical practice would provide information regarding areas of opportunity for AI to affect real-world patient care [14]. We conducted a systematic review of all RCTs studying AI-assisted tools in clinical care.


Search Strategy

The systematic review was conducted following the updated PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 guidelines [15]. We comprehensively searched CINAHL, Cochrane Central, Embase, MEDLINE, and PubMed from inception to July 14, 2021, to identify RCTs of AI-based tools across all medical specialties. Details of the full search strategy are provided in Multimedia Appendix 1. The search strategy included a combination of keywords and standardized Medical Subject Headings terms: “Artificial Intelligence,” “Deep Learning,” “Computer-Assisted Diagnosis,” “Computer Assisted Diagnosis,” “Computational Intelligence,” “Computer Reasoning,” “Computer Vision System,” “Knowledge Acquisition,” “Knowledge Representation,” “Machine Intelligence” or “Machine Learning” or “Transfer Learning” or “Hierarchical Learning.” The search was limited to RCTs. We also hand searched the references of the included studies to identify additional studies of interest. To include as many previous endeavors in this research area as possible, our search was not limited to peer-reviewed information. Conference abstracts and preprints were also included. The authors had no funding source for this study. This study was registered on PROSPERO (CRD42021286539).

Study Selection

After removing duplicates, two study authors (TYTL and MFKC) independently screened the title, abstract, and full text (if available) of each article to determine their eligibility. Unresolved disagreements were resolved by consulting the senior author (JJYS). Discrepancies were resolved by consensus. The complete manuscript was downloaded if the study met the inclusion criteria. We included studies that met the following inclusion criteria: (1) application of AI-assisted tools in clinical practice, which is defined as diagnosis, treatment, and prognostication on medical conditions that are seen and managed in daily clinical practice in hospitals or clinics. This does not include cellular or tissue cultures, animal studies, or experimental conditions such as induced cardiac arrhythmia and metabolic abnormalities. We classified the tool as AI-powered if the expressions, “artificial intelligence,” “AI,” “machine learning,” “deep learning,” “deep neural network,” and “neural network” were used to describe the tool within the articles or other publicly available information resources; (2) patients or health care providers must be involved; (3) study design must be an RCT; and (4) control group must be without AI assistance. The exclusion criteria were as follows: (1) studies without implementation of clinical AI-assisted tools for patient management; (2) studies that were not conducted as original RCTs, for example, secondary analysis of a published RCT; and (3) clinical outcome not clearly defined. Reasons for exclusion were also recorded.

Data Extraction

After identifying relevant studies, the same two authors (TYTL and MFKC) independently extracted the data from each included study. Study design (racial information, sample size, RCT setting and design, and AI intervention and control) and AI-assisted tool characteristics (AI-assisted tool name, AI subtype, data type, and training and validation data) were documented. If AI development–related data were not available in the included articles, previously published articles of the same AI-assisted tool were reviewed to obtain the relevant information. Study end points (performance metrics used in primary and secondary end points) were listed. Clinically relevant end points were defined as whether the AI-assisted tools led to subsequent clinical interventions focusing on specific end points: (1) further diagnostic workup and investigation of the medical conditions, (2) changes in treatment strategy, (3) requirement of hospitalization, (4) escalation of care to the intensive care unit, and (5) influence on survival and mortality. Two independent researchers (TYTL and MFKC) resolved disagreements through discussion. If there were unresolved disagreements, consultation from senior author (JJYS) was sought.

Assessment of Risk of Bias

Risk of bias was assessed using the Cochrane risk-of-bias tool for randomized trials [16]. We specifically assessed the risk of bias of randomization process, deviations from intended interventions, missing outcome data, measurement of the outcome, and selection of the reported results. The overall risk of bias was classified as low, some concerns, or high.


Overview

The search performed on July 14, 2021, yielded 11,839 articles (n=2232, 18.85% from MEDLINE; n=1406, 11.88% from Embase; n=2264, 19.12% from PubMed; n=5229, 44.17% from Cochrane Central; and n=708, 5.98% from CINAHL); of these, 6823 (57.63%) were screened after removal of duplicates (n=5016, 42.37%). After screening the titles and abstracts, 6676 articles were excluded, because they did not fulfill the inclusion criteria. A total of 147 full manuscripts were individually assessed, of which 34 (23.1%) met the inclusion criteria. In addition, 4 more articles were identified by examining the references of the listed articles and manual searches (Figure 1). A total of 39 articles were included in this systematic review [6,17-54] as listed in Table 1.

Figure 1. PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) flow diagram.
View this figure
Table 1. Publications.
Author (publication year)TitleCountryArticle typeSpecialty
El Solh et al [17], 2009Predicting optimal CPAP by neural network reduces titration failure: a randomized studyThe United StatesOriginal articleRespiratory medicine
Shimabukuro et al [18], 2017Effect of a machine learning-based severe sepsis prediction algorithm on patient survival and hospital length of stay: a randomised clinical trialThe United StatesOriginal articleAnesthesiology
Labovitz et al [6], 2017Using artificial intelligence to reduce the risk of nonadherence in patients on anticoagulation therapyThe United StatesOriginal articleNeurology
Gracey et al [19], 2018Improving medication adherence by better targeting interventions using artificial intelligence-a randomized control studyThe United StatesAbstractFamily medicine
Liu et al [20], 2018Evaluating the impact of an integrated computer-based decision support with person-centered analytics for the management of hypertension: a randomized controlled trialChinaAbstractCardiology
Vennalaganti et al [21], 2018Increased detection of Barrett’s esophagus–associated neoplasia using wide-area trans-epithelial sampling: a multicenter, prospective, randomized trialThe United StatesOriginal articleGastroenterology and hepatology
Biester et al [22], 2019DREAM5: An open-label, randomized, cross-over study to evaluate the safety and efficacy of day and night closed-loop control by comparing the MD-Logic automated insulin delivery system to sensor augmented pump therapy in patients with type 1 diabetes at homeGermany, Israel, and SloveniaOriginal articleEndocrinology, diabetes, and metabolism
Pouska et al [23], 2019The use of HPI (Hypotension probability indicator) during major intracranial surgery; preliminary results of a prospective randomized trialCzech RepublicAbstractAnesthesiology
Lin et al [24], 2019Diagnostic efficacy and therapeutic decision-making capacity of an artificial intelligence platform for childhood cataracts in Eye Clinics: a multicenter randomized controlled trialChinaOriginal articleOphthalmology
Kamdar et al [25], 2019A randomized controlled trial of a novel artificial intelligence–based smartphone application to optimize the management of cancer-related painThe United StatesAbstractClinical oncology
Persell et al [26], 2020Effect of home blood pressure monitoring via a smartphone hypertension coaching application or tracking application on adults with uncontrolled hypertension: a randomized clinical trialThe United StatesOriginal articleCardiology
Voss et al [27], 2019Effect of wearable digital intervention for improving socialization in children with autism spectrum disorder: a randomized clinical trialThe United StatesOriginal articlePsychiatry
Wang et al [28], 2019Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled studyChinaOriginal articleGastroenterology and hepatology
Wu et al [29], 2019Randomised controlled trial of WISENSE, a real-time quality improving system for monitoring blind spots during esophagogastroduodenoscopyChinaOriginal articleGastroenterology and hepatology
Pavel et al [30], 2020A machine-learning algorithm for neonatal seizure recognition: a multicentre, randomised, controlled trialIreland, the Netherlands, Sweden, and the United KingdomOriginal articleNeurology
Alfonsi et al [31], 2020Carbohydrate counting app using image recognition for youth with type 1 diabetes: pilot randomized control trialCanadaOriginal articleEndocrinology, diabetes, and metabolism
Auloge et al [32], 2020Augmented reality and artificial intelligence–based navigation during percutaneous vertebroplasty: a pilot randomised clinical trialFranceOriginal articleOrthopedics and traumatology
Avari et al [33], 2020Safety and feasibility of the PEPPER adaptive bolus advisor and safety system; a randomized control studyThe United Kingdom and SpainOriginal articleEndocrinology, diabetes, and metabolism
Chen et al [34], 2020Comparing blind spots of unsedated ultrafine, sedated, and unsedated conventional gastroscopy with and without artificial intelligence: a prospective, single-blind, 3-parallel-group, randomized, single-center trialChinaOriginal articleGastroenterology and hepatology
Gong et al [35], 2020Detection of colorectal adenomas with a real-time computer-aided system (ENDOANGEL): a randomised controlled studyChinaOriginal articleGastroenterology and hepatology
Liu et al [36], 2020 The single-monitor trial: an embedded CADe system increased adenoma detection during colonoscopy: a prospective randomized studyChinaOriginal articleGastroenterology and hepatology
Nicolae et al [37], 2020Conventional vs machine learning-based treatment planning in prostate brachytherapy: results of a phase I randomized controlled trialCanadaOriginal articleClinical oncology
Repici et al [38], 2020Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trialItalyOriginal articleGastroenterology and hepatology
Su et al [39], 2020Impact of a real-time automatic quality control system on colorectal polyp and adenoma detection: a prospective randomized controlled study (with videos)ChinaOriginal articleGastroenterology and hepatology
Wang et al [40], 2020Lower adenoma miss rate of computer-aided detection-assisted colonoscopy vs routine white-light colonoscopy in a prospective tandem studyChinaOriginal articleGastroenterology and hepatology
Wang et al [41], 2020Effect of a deep-learning computer-aided detection system on adenoma detection during colonoscopy (CADe-DB trial): a double-blind randomised studyChinaOriginal articleGastroenterology and hepatology
Wijnberge et al [42], 2020Effect of a machine learning-derived early warning system for intraoperative hypotension vs standard care on depth and duration of intraoperative hypotension during elective noncardiac surgery: the HYPE randomized clinical trialThe NetherlandsOriginal articleAnesthesiology
Weisinger et al [43], 2021Artificial intelligence-powered non-invasive and frequency-tuned electromagnetic field therapy improves upper extremity motor function in sub-acute stroke patients: a pilot randomized controlled trialIsraelAbstractNeurology
Blomberg et al [44], 2021Effect of machine learning on dispatcher recognition of out-of-hospital cardiac arrest during calls to emergency medical services: a randomized clinical trialDenmarkOriginal articleEmergency medicine
Browning et al [45], 2021The clinical effectiveness of using a predictive algorithm to guide antidepressant treatment in primary care (PReDicT): an open-label, randomised controlled trialThe United Kingdom, Spain, Germany, France, and the NetherlandsOriginal articlePsychiatry
Jayakumar et al [46], 2021Comparison of an artificial intelligence-enabled patient decision aid vs educational material on decision quality, shared decision-making, patient experience, and functional outcomes in adults with knee osteoarthritis: a randomized clinical trialThe United StatesOriginal articleOrthopedics and traumatology
Kamba et al [47], 2021A multicentre randomized controlled trial to verify the reducibility of adenoma miss rate of colonoscopy assisted with artificial intelligence–based softwareJapanAbstractGastroenterology and hepatology
Luo et al [48], 2021Artificial intelligence-assisted colonoscopy for detection of colon polyps: a prospective, randomized cohort studyChinaOriginal articleGastroenterology and hepatology
Rafferty et al [49], 2021A novel mobile app (Heali) for disease treatment in participants with irritable bowel syndrome: randomized controlled pilot trialThe United StatesOriginal articleGastroenterology and hepatology
Repici et al [50], 2021Artificial intelligence and colonoscopy experience: lessons from two randomised trialsItaly and SwitzerlandOriginal articleGastroenterology and hepatology
Strömblad et al [51], 2021Effect of a predictive model on planned surgical duration accuracy, patient wait time, and use of presurgical resources: a randomized clinical trialThe United StatesOriginal articleSurgery
Wu et al [52], 2021Evaluating the effects of an artificial intelligence system on endoscopy quality and preliminarily testing its performance on detecting early gastric cancer: a randomized controlled trialChinaOriginal articleGastroenterology and hepatology
Yao et al [53], 2021Artificial intelligence-enabled electrocardiograms for identification of patients with low ejection fraction: a pragmatic, randomized clinical trialThe United StatesOriginal articleCardiology
Brown et al [54], 2021Deep learning computer-aided polyp detection reduces adenoma miss rate: a US multi-center randomized tandem colonoscopy study (CADeT-CS trial)The United StatesOriginal articleGastroenterology and hepatology

Study Characteristics

There were very few RCTs on AI-assisted medicine published until 2017. There was 1 RCT published in 2009, and the remaining 38 were published in the past 5 years (2 in 2017, 3 in 2018, 7 in 2019, 14 in 2020, and 12 in the first half of 2021; Figure 2).

These RCTs were conducted across 16 countries in North America, Europe, and Asia, with most of them conducted in the United States (13/39, 33%) and China (12/39, 31%). Furthermore, 18% (7/39) of the RCTs were published as conference abstracts only. Of these 39 publications, 16 (41%) were related to gastroenterology, whereas other specialties included anesthesiology (n=3, 7.7%), cardiology (n=3, 7.7%), endocrinology (n=3, 7.7%), psychiatry (n=2, 5%), neurology (n=3, 7.7%), orthopedics (n=2, 5%), oncology (n=2, 5%), surgery (n=1, 2.6%), ophthalmology (n=1, 2.6%), respiratory medicine (n=1, 2.6%), family medicine (n=1, 2.6%), and emergency medicine (n=1, 2.6%; Figure 3).

Figure 2. Number of randomized controlled trials of artificial intelligence–assisted medicine per year.
View this figure
Figure 3. Distribution of original of publications and specialty.
View this figure

Study Design

Multimedia Appendix 2 shows the study design and AI-assisted tool characteristics of each selected RCT. Most studies were single centered with a limited number of patients. Of these 39 studies, 35 (90%) had a sample size <1000 participants, 11 (28%) studies recruited fewer than 100 participants, 2 (5%) studies had a sample size of >1000 participants, and only 2 (5%) studies recruited >10,000 participants. More than half of the included RCTs (23/39, 59%) were conducted in a single center, 36% (14/39) of the studies were conducted across multiple centers, and 5% (2/39) of the studies did not mention how many centers were involved. A total of 16 open-label studies were conducted. Only 7 studies mentioned the racial information of the participants. A total of 13 blinded randomized trials were identified, of which 4 (31%) were double blinded and 9 (69%) were single blinded. The remaining 10 studies did not mention the level of blinding. Furthermore, 8 studies had a crossover study design. Most RCTs (36/39, 92%) compared the AI-assisted tools to control arms using the standard of care. Furthermore, 5% (2/39) of the studies used a sham treatment without AI assistance as the control group. A study used a mobile app without AI assistance as the control arm.

AI-Assisted Tool Characteristics

Biosignal-based AI tools are more common than clinical data–based tools. A total of 26 AI-assisted tools were biosignal based. Endoscopic images were the most commonly used biosignal (15/26, 58%). Furthermore, 50% (13/26) of the AI-assisted tools used clinical or biochemical data for analysis (patients’ demography, self-administered questionnaire, and other relevant clinical data such as blood test results, blood pressure, and continuous positive airway pressure). No AI-assisted tool used both biosignal and clinical data combined as source data in the algorithm.

Most AI-assisted tools relied on static data (34/39, 87%) input to build the algorithm instead of dynamic data input (5/39, 13%). Static data refer to a snapshot of image or data of patients at a specific time point, whereas dynamic data are those captured continuously over a certain period during the study. For example, still images of the intestinal lumen captured during colonoscopy for AI-assisted adenoma detection are static data, whereas hourly captured vital signs and selected available laboratory tests for AI-assisted prediction of severe sepsis are dynamic data [18].

Approximately half of the studies (19/39, 49%) reported the AI-assisted tools development process. Of these, three AI-assisted tools in 8 studies, namely, GI-Genius, EndoScreener, and CC-Cruiser, were developed using data from multiple centers, whereas others were developed using data from a single center. A total of 35 studies reported the AI developer. Of these, 18 (51%) AI-assisted tools were developed by industry and 17 (49%) were developed by academic institutions.

Study End Points

Table 2 presents the study objectives and end points. Approximately half of the studies (18/39, 46%) used diagnostic accuracy as primary end point. The most common diagnostic end point is adenoma or polyp detection rate during colonoscopy. A total of 13 studies measured treatment response after AI-assisted intervention. Quality assurance of interventions was examined in 7 studies. End point measures of 27 studies were considered clinically relevant: 19 (70%) led to further investigation, 6 (22%) indicated the need for change in treatment, 1 (4%) reported in-hospital mortality and length of hospitalization, and 1 (4%) reported hospital admission.

Table 2. Study objectives and end points (primary and secondary).
Author (publication year)Study objectivePrimary end pointSecondary end pointClinical relevance
El Solh et al [17], 2009To test the effectiveness of an ANNa application for CPAPb titration on the time required to achieve an optimal CPAP pressure and CPAP titration failureTime to optimal CPAP pressureTitration failure rateChange of treatment
Shimabukuro et al [18], 2017To test the use of a machine learning–based severe sepsis prediction system for reductions in average length of stay and in-hospital mortality rateAverage hospital length of stayIn-hospital mortality rate; ICUc length of stayMortality and hospital and ICU length of stay
Labovitz et al [6], 2017To evaluate the use of an artificial intelligence platform on mobile devices in measuring and increasing medication adherence in patients with stroke on anticoagulation therapyMedication adherenceNilNil
Gracey et al [19], 2018To evaluate the effectiveness of using artificial intelligence to target which patients should receive interventions compared with traditional targeting approaches to improve medication adherenceMedication adherenceNilNil
Liu et al [20], 2018To assess the effects of clinical decision support system of graph-based machine learning algorithms on blood pressure management and economic burden of diseaseBlood pressure reduction in patients with hypertensionEconomic burdenChange of treatment
Vennalaganti et al [21], 2018To evaluate the use of WATSd as an adjunct to biopsy sampling for the detection of HGDe or EACf in a referral population with BEgRate of detection of HGD or EACNeoplasia detection rates based on the procedure order (WATS vs biopsy sampling first) of each procedure separately and the additional time required for WATSFurther investigation
Biester et al [22], 2019To evaluate the safety and efficacy of 60-hour glucose control using the MD-Logic system in individuals with type 1 diabetes at home for day and night use, particularly without remote monitoringPercentage of glucose sensor readings within 70 to 180 mg/dL (3.9-10 mmol/L)Percentage of glucose sensor readings <60 to 70 mg/dL (3.3-3.9 mmol/L), percentage of glucose sensor readings >180 to 240 mg/dL (10-13.3 mmol/L), average and SD of glucose sensor readings, and overnight percentage of readings (“overnight” defined as 11:00 PM-7:00 AM) <70 mg/dL (3.9 mmol/L)Further investigation
Pouska et al [23], 2019To assess the use of HPIh to avoid hypotension in major intracranial surgeryNumber of hypotension events; duration of hypotension eventsNumber of hypotension events in maintenance phase of anesthesiaFurther investigation
Lin et al [24], 2019To compare the diagnostic efficacy and treatment decision-making capacity between CC-Cruiser and ophthalmologists in real-world clinical settingsAccuracy of the diagnosis normal lens versus cataractEvaluation of the disease severity; time required for making the diagnosis; patient satisfactionFurther investigation
Kamdar et al [25], 2019To examine the impact of ePAL on cancer pain severity, attitudes toward cancer pain, and health care usePain severityAttitudes toward cancer treatment (Barriers Questionnaire II); anxiety (General anxiety Disorder-7); pain-related hospital admissionsHospitalization
Persell et al [26], 2020To evaluate the effectiveness of an artificial intelligence smartphone coaching app to promote hypertension self-managementSBPi measured at 6 monthsSelf-reported medication adherence; home monitoring and self-management practices; self-efficacy related to BPj and BMI; self-reported health behaviorsChange of treatment
Voss et al [27], 2019To test the efficacy of a wearable machine learning tool for intervention on a core ASDk deficit in the natural home environment SRS-IIl total score; Vineland Adaptive Behavioural Scales, Second edition; Developmental Neuropsychological Assessment, Second edition; Emotion Guessing GameModerator analysis; child behavior checklist; and the Vineland Adaptive Behavioural Scales, Second edition adaptive composite scoreNil
Wang et al [28], 2019To investigate whether a high-performance real-time automatic polyp detection system can increase polyp and ADRsm in the real clinical settingADRPDRn; mean number of polyps detected per colonoscopy; mean number of adenomas detected per colonoscopy; rate of false positives and false negativesFurther investigation
Wu et al [29], 2019To evaluate the effectiveness of WISENSE to monitor blind spots, time the procedure, and automatically generate photo documentation during EGDo and thus raise the quality of everyday endoscopyBlind spot rateInspection time; completeness of photo documentation generated by endoscopists; completeness of photo documentation generated by WISENSE in WISENSE group; completeness of photo documentation generated by WISENSE and endoscopists in WISENSE group; the percentage of patients being ignored in each siteFurther investigation
Pavel et al [30], 2020To evaluate the performance of the ANSeRp algorithm in real time by assessing the diagnostic accuracy for the detection of neonatal electrographic seizures with and without the use of ANSeR as a support tool for clinicians at the cot sideDiagnostic accuracy (sensitivity, specificity, and false detection rate) of health care professionals to identify neonates with electrographic seizures and seizure hours with and without the support of the ANSeR algorithmSummary measures of seizure burden (total seizure burden, maximum hourly seizure burden, and median seizure duration); number of inappropriate antiseizure medications givenChange of treatment
Alfonsi et al [31], 2020To test the app’s usability and potential impact on carbohydrate counting accuracyCarbohydrate counting accuracyQuality of life for youth; self-care; patient or parent responsibilityNil
Auloge et al [32], 2020To evaluate technical feasibility, accuracy, safety, and patient radiation exposure granted by a novel navigational tool integrating augmented reality and artificial intelligence during percutaneous vertebroplasty of patients with vertebral compression fracturesTechnical feasibility of trocar placement using augmented reality or artificial intelligence guidanceComparison between groups A and B in terms of accuracy, procedural safety, time for trocar placement, and patient radiation exposure (dose area product and fluoroscopy time)Nil
Avari et al [33], 2020To evaluate the safety and efficacy of the PEPPER system compared with a standard bolus calculatorDifference in change in percentage time in range (3.9-10.0 mmol/L; 70-180 mg/dL) between the intervention arm that receives the PEPPER safety system with adaptive bolus advice and the control armPercentage time spent in euglycemia, hypoglycemia, and hyperglycemia; number of episodes of serious hypoglycemia; episodes of hypoglycemia within 5 hours postprandially; severe hypoglycemia (defined as a hypoglycemia event requiring third party assistance); postprandial mean area under the curve at 5 hours (expressed as mmol/L min); glycemia risk and variability measuresChange of treatment
Chen et al [34], 2020To compare blind spots of sedated C-EGDq, unsedated U-TOEr, and unsedated C-EGD with and without the assistance of ENDOANGThe blind spot of 3 types of EGD with the assistance of ENDOANGELBlind spot rate of unsedated U-TOE and unsedated and sedated C-EGD with or without the assistance of ENDOANGEL; consistency between ENDOANGEL and endoscopists’ reviewFurther investigation
Gong et al [35], 2020To evaluate whether the ENDOANGEL system could improve polyp yield during colonoscopyADRThe ADR for adenomas of different sizes (diminutive [≤5 mm], small [>5 to<10 mm], and large [≥10 mm]); locations (cecum, ascending colon, transverse colon, descending colon, sigmoid colon, and rectum); PDR; PDR for polyps of different sizes; locations; mean number of adenomas per patient; mean number of polyps per patient; withdrawal time (time spent viewing as the endoscope is withdrawn during a colonoscopy, excluding biopsy or treatment time); adverse events and serious adverse eventsFurther investigation
Liu et al [36], 2020To investigate whether the integration of a CADes system into the primary monitor used during colonoscopy may increase polyp and adenoma detection without increasing physician fatigueADRPDR; polyps per colonoscopy and adenomas per colonoscopyFurther investigation
Nicolae et al [37], 2020To evaluate the noninferiority of day 30 dosimetry between a machine learning–based treatment planning system for prostate low-dose-rate brachytherapy and the conventional manual planning techniqueThe 1-month postoperative follow-up results between expert-planned low-dose-rate treatments (conventional) and the PIPAt machine learning approachThe efficiency of the PIPA approach in a standardized preoperatively planned workflow; total treatment planning time; need and extent of modificationsNil
Repici et al [38], 2020To assess the safety and efficacy of a CADe system in detection of colorectal neoplasias during real-time colonoscopyADRProximal ADR; total number of polyps detected; sessile serrated lesion detection rate; mean number of adenomas per colonoscopy; cecal intubation rate; withdrawal timeFurther investigation
Su et al [39], 2020To develop an automatic quality control system and assess whether it could improve polyp and adenoma detection in clinical practiceADRPDR; mean number of adenomas detected per colonoscopy; mean number of polyps detected per colonoscopy; withdrawal time (biopsy time was excluded by stopping the clock); adequate bowel preparation rate, defined as the percentage of colonoscopies with each segmental BBPSu score 2Further investigation
Wang et al [40], 2020To compare adenoma miss rates of CADe colonoscopy vs routine white-light colonoscopy.Adenoma miss ratePolyp miss rate; miss rate of advanced adenomas; sessile serrated adenoma or polyps; patient miss rate; ADR for the first pass; adenoma per colonoscopy; polyp per colonoscopyFurther investigation
Wang et al [41], 2020To perform a double-blinded study using a sham control to more rigorously assess the effectiveness of a CADe system for improving detection of colon adenomas and polyps. We also aimed to analyze the characteristics of polyps missed by endoscopistsADRPDR; number of polyps per colonoscopy; number of adenomas per colonoscopy; sensitivity; specificity of the 3 skilled endoscopistsFurther investigation
Wijnberge et al [42], 2020To test whether the clinical application of the early warning system in combination with a hemodynamic diagnostic guidance and treatment protocol reduces intraoperative hypotensionTime-weighted average of hypotension during surgeryIncidence of hypotension (the number of hypotensive events per patient): total time with hypotension and percentage of time spent with hypotension during surgery; incidence of hypertension (the number of hypotensive events per patient): total time with hypertension and percentage of time spent with hypertension during surgeryFurther investigation
Weisinger et al [43], 2021To explore the benefit of BrainQ’s novel and noninvasive, artificial intelligence–powered, frequency-tuned ELF-EMFv treatment (BQ) in improving upper extremity motor function in a population with subacute ischemic strokeFugl-Meyer Assessment-Upper Extremity scoreModified Rankin Scale; Action Research Arm Test; Box and Block Test; NIHSSwNil
Blomberg et al [44], 2021To examine how a machine learning model trained to identify OHCAx and alert dispatchers during emergency calls affected OHCA recognition and responseRate of dispatchers’ recognition of subsequently confirmed OHCADispatchers’ time to recognition of OHCA; rate of DA-CPRyChange of treatment
Browning et al [45], 2021To assess the clinical effectiveness of using a predictive algorithm based on behavioral tests of affective cognition and subjective symptoms and to guide antidepressant treatmentTreatment response of depression symptomsChange in anxiety scores at week 8 (measured using the Generalized Anxiety Disorder Assessment, 7 item version [30]); remission of depression at week 8 (defined as QIDS-SR-16z score of ≤5); change in the individual item scores from the QIDS-SR-16 measuring restlessness and sadness at week 8; change in symptoms of depression (treated as a continuous variable) across 12 months (measured using QIDS-SR-16); change in observer-reported symptoms of depression (treated as dichotomous response and as a continuous variable and measured using the MADRSaa at week 8); change in functional outcome across 12 months (measured using the SASab screener); patients also completed detailed health economic, acceptability, and cognitive functioning measures that will be reported separatelyNil
Jayakumar et al [46], 2021To assess the effect of an artificial intelligence–enabled patient decision aid that includes education, preference assessment, and personalized outcome estimations (using patient-reported outcome measurements) on decision quality, patient experience, functional outcomes, and process-level outcomes among individuals with advanced knee osteoarthritis considering total knee replacement in comparison with education onlyDecision process score of the knee decision quality instrument questions 3.1 to 3.5Level of shared decision-making (assessed using the CollaboRATE survey); patient satisfaction with the consultation (numerical rating scale); condition-specific symptoms and functional limitations (Knee Injury and Osteoarthritis Outcome Score, Joint Replacement); duration of consultation in minutes; total knee replacement rates (proportion of patients undergoing surgery); treatment concordance (knee decision quality instrument question 1.6)Nil
Kamba et al [47], 2021To clarify whether adenoma miss rate could be reduced with the CADe assistance during screening and surveillance colonoscopyAdenoma miss ratePolyp miss rate; sessile serrated lesion miss rate; ADRFurther investigation
Luo et al [48], 2021To explore whether artificial intelligence–assisted colonoscopy could improve the PDR in the actual clinical environmentPDRNumber of polyps detected; the number of diminutive polyps (diameter <6 mm); the number of polyps of each Paris type detected; the number of false positive resultsFurther investigation
Rafferty et al [49], 2021To determine whether Heali, a novel artificial intelligence dietary mobile app can improve adherence to the LFDac, IBSad symptom severity and quality of life outcomes in adults with IBS or IBS-like symptoms over a 4-week periodAdherence to the LFDIBS symptom severity; quality of life outcomesNil
Repici et al [50], 2021To assess the efficacy of a CADe system in detection of colorectal neoplasias in a nonexpert setting to challenge the CADe impact in a real-life scenarioADRProximal ADR; total number of polyps detected; sessile serrated lesion detection rate; mean number of adenomas per colonoscopy; cecal intubation rate; withdrawal timeFurther investigation
Strömblad et al [51], 2021To assess accuracy and real-world outcome from implementation of a machine learning model that predicts surgical case durationAccurate prediction of the duration of each scheduled surgeryEffects on patients and systems were measured by start time delay of following cases; time between cases; the time patients spent in presurgical areaNil
Wu et al [52], 2021To verify the effectiveness of ENDOANGEL in improving endoscopy quality and pretest its performance in detecting EGCae in a multicenter randomized controlled trialNumber of blind spotsPerformance of ENDOANGEL in predicting early gastric cancer in a clinical settingFurther investigation
Yao et al [53], 2021To assess whether an ECG-based, artificial intelligence–powered clinical decision support tool enables early diagnosis of low EFaf, a condition that is underdiagnosed but treatableRate of newly diagnosed low EF, defined as EF≤50% within 90 daysCompletion of an ECG within 90 days; other findings (eg, valvular heart disease), except low EF present on ECGsFurther investigation
Brown et al [54], 2021To assess the comparative adenoma miss rate for CADe-assisted colonoscopy when compared with high-definition white light colonoscopy aloneAdenoma miss ratePolyp miss rate; hyperplastic polyp miss rate; sessile serrated lesion miss rate; ADR; PDR; adenoma per colonoscopy; polyp per colonoscopy; sessile serrated lesion per colonoscopyFurther investigation

aANN: artificial neural network.

bCPAP: continuous positive airway pressure.

cICU: intensive care unit.

dWATS: wide-area transepithelial sampling.

eHGD: high-grade dysplasia.

fEAC: esophageal adenocarcinoma.

gBE: Barrett’s esophagus.

hHPI: hypotension probability indicator.

iSBP: systolic blood pressure.

jBP: blood pressure.

kASD: autism spectrum disorder.

lSRS-II: Social Responsiveness Scale II.

mADR: adenoma detection rate.

nPDR: polyp detection rate.

oEGD: esophagogastroduodenoscopy

pANSeR: Algorithm for Neonatal Seizure Recognition.

qC-EGD: conventional esophagogastroduodenoscopy.

rU-TOE: ultrathin transoral endoscopy.

sCADe: computer-assisted detection.

tPIPA: prostate implant planning algorithm.

uBBPS: Boston Bowel Preparation Scale.

vELF-EMF: extremely low frequency and low intensity electromagnetic fields.

wNIHSS: National Institutes of Health Stroke Scale.

xOHCA: out-of-hospital cardiac arrest.

yDA-CPR: dispatcher-assisted cardiopulmonary resuscitation.

zQIDS-SR-16: Quick Inventory of Depressive Symptomatology (16-Item) (Self-Report).

aaMADRS: Montgomery-Åsberg Depression Rating Scale.

abSAS: Social Adjustment Scale.

acLFD: low fermentable oligo-, di-, mono-saccharides and polyols diet.

adIBS: irritable bowel syndrome.

aeECG: electrocardiogram.

afEF: ejection fraction.

Study Outcomes

Table 3 shows the study results and limitations of each RCT. Of the 39 RCTs, 30 (77%) reported a positive study outcome where AI-assisted interventions outperformed the control arms. Of these 30 studies with positive outcomes, 22 (73%) AI-assisted interventions were biosignal based, and 8 (27%) studies used clinical data–based AI-assisted intervention for clinical outcome improvement. In addition, 21 of these 30 (70%) studies reported positive results of clinically relevant end points. Of these, 18 (86%) led to further investigations, 1 (5%) led to change in treatment, and 2 (9%) reduced the length of hospitalization.

Table 3. Study results and limitations.
Author (publication year)Primary end point resultSecondary end point resultStudy outcomeUnderpoweredStudy conclusionLimitations
El Solh et al [17], 2019Time to optimal CPAPa pressure: AIb mean 198.7 (SD 143.8) minutes versus control mean 284.0 (SD 126.5) minutesTitration failure: AI 16% versus control 36%; drop of residual obstructive apnea–hypopnea events and oxygen desaturationsPositiveNoMaximizing the time to achieve optimal CPAP and in reducing CPAP titration failureSingle center only; possible analysis bias as technologists were not blinded
Shimabukuro et al [18], 2017AI 10.3 days versus control 13 daysIn-hospital mortality: AI 8.96% versus control 21.3%; ICUc length of stay: AI 6.31 days versus control 8.40 daysPositiveNoSignificant decrease in the hospital LOSd and in-hospital mortalitySmall sample size; heterogenous population; trial was conducted in the 2 ICUs only; metrics were not monitored prospectively during the study because of the likely misrepresentation of such results; false positive rate, sensitivity, and prediction rate may be affected as clinicians may have initiated treatment before severe sepsis onset owing to advanced notice from the predictive algorithm; the use of overall metrics, LOS, and in-hospital mortality for all comers may underestimate the impact of the intervention on outcomes for patients with sepsis; potential for competing risks in the selected end points, mortality may shorten a patient’s LOS; this study was patient-outcome oriented
Labovitz et al [6], 2017Mean (SD) cumulative adherence based on pill count was 97.2 (4.4%) for the AI platform group and 90.6% (5.8%) for the control group. Plasma drug concentration levels indicated that adherence was 100% (15/15) and 50% (6/12) in the intervention and control groups, respectivelyNilPositiveUnknownReal-time monitoring has the potential to increase adherence and change behavior, particularly in patients on direct oral anticoagulant therapyNot mentioned
Gracey et al [19], 2018Likelihood of being adherent: AI>control, 6.11%; likelihood of being adherent: AI>traditional, 7.8%; no significant difference in likelihood of being adherentNilPositiveUnknownUsing AI to target interventions can increase the effectiveness of medication adherence intervention programsNot mentioned
Liu et al [20], 2018AI versus control: no significant differenceEconomic burden of disease—AI versus control (all): no significant difference; economic burden of disease—AI: 46,006 (SD 40,831) yuan (US $6901 [SD 6125]) versus control (in surgical dept): 64,192 (SD 67,968) yuan (US $9629 [SD 10195])); benefit-cost ratio of AI: 1.15; net present value of benefit-cost of AI: 5792 yuan; direct medical costs—AI: 43,467 (SD 39.716) versus control: 61,205 (SD 66,576) yuanNegativeUnknownA clinical decision support system based on the graph-based machine learning algorithms changed the antihypertensive prescriptions and reduced the medical expense among patients with hypertensionNot mentioned
Vennalaganti et al [21], 2018HGDe or EACf detection—WATSg alone: 29 versus control alone: 7; AI (alone)>control (alone) 4.2 timesNeoplasia detection rates: not mentioned; average time required for WATS; additional time required for WATS: 11 minutes 26 seconds versus control: 6 minutes 55 secondsPositiveUnknownWATS increases the detection of HGD and EAC in a high-risk BEh surveillance population when used as an adjunct to biopsy sampling compared with biopsy sampling aloneSingle center research only; potential of population bias as study population (20%) was enriched with patients with BE with a known history of dysplasia or referred for endoscopic therapy; no long-term follow-up
Biester et al [22], 2019AI: 66.6% versus control: 59.9%Percentage <60 mg/dL—AI: 0.64% versus control: 0.38%; percentage <70 mg/dL—AI: 2.31% versus control: 1.45%; percentage >180 mg/dL—AI: 28.32% versus control: 36.43%; percentage >240 mg/dL—AI: 8.53% versus control: 8.71%; Mean —AI: median (IQR) 153.11 (142.33-174.81) versus control: 163.84 (150.17-186.54); SD—AI: median (IQR) 52.71 (44.75-66.39) versus control: 54.95 (46.19-69.19)PositiveNoThe MD-Logic system was safe and associated with better glycemic control than SAPi therapy for day and night use. The absence of remote monitoring did not lead to safety signals in adapting basal rates nor in administration of automated bolus correctionsHigh rate of communication errors between the tablet computer running the algorithm and the insulin pump
Pouska et al [23], 2019No significant difference in number of hypotension events between 2 groups (4/20 vs 2/20)AI: 10 versus control: 4NegativeUnknownOn the basis of our data, it seems that the inclusion of HPIj into a goal-directed treatment strategy could lower the incidence of hypotension within maintenance phase of anesthesiaNot mentioned
Lin et al [24], 2019Accuracy—AI: 87.4% versus control: 99.1%No significant difference in evaluation of the disease severity between AI and control; AI: 2.79 minutes versus control: 8.53 minutes; rating of overall satisfaction—AI: mean 3.47 (SD 0.501) versus control: mean 3.38 (0.554)NegativeNoCC-Cruiser exhibited less accuracy compared with senior human consultants in diagnosing childhood cataracts and making treatment decisions, but it has the capacity to assist human physicians in clinical practice in its current statePatients without symptoms were less willing to participate in; patients with slightly opaque lens may have missed; CC-Cruiser provided treatment suggestions without considering the patients’ general conditions; lack of internet accessibility limited the implementation of CC-Cruiser in low-income areas; possibly sufficient statistic power because cluster RCTk was adopted in trial, whereas RCT was used in sample size calculation
Kamdar et al [25], 2019Difference of BPIl between AI and control: ß=−.09Difference of BQ-IIm between AI and control: ß=−.037; difference of General Anxiety Disorder-7 between AI and control: ß=.21; AI: 4 versus control: 20PositiveUnknownAI significantly decreases pain scores and pain-related hospitalizations in patients with cancer-related painNot mentioned
Persell et al [26], 2020AI: mean systolic blood pressure (SD) 132.3 (15.0) mm Hg versus control: 135 (13.9) mm HgSignificant improvement in self-reported medication adherence in AI group than control; no significant difference between home monitoring and self-management practices; AI group has 26.7 minutes per week (−5.4 to 58.8) more than control group in self-reported physical activityNegativeUnknownAdults with hypertension randomized to a coaching app plus home monitor had similar SBPn compared with controls receiving a tracking app and home monitorBlinding to participants and research staff is impossible; some outcomes were self-reported; not specifically select participants who were likely to use a health-coaching app; small sample size; the app used in the study was a beta version; the AI and machine learning technology used here in this app gains information with larger numbers of users contributing data; cannot exclude the possibility that some patients may have well-controlled hypertension; limited generalizability because only iOS device users were recruited
Voss et al [27], 2019SRS-IIo showed large, not significant, positive mean changes in treatment participants; the VABS-IIp socialization subscale score significantly increased between the start and end of the intervention in treatment-to-control comparisonsModerator analyses showed a moderation effect for girls showing greater improvement; no significant changes from intake to posttest 1 were observed on Child Behaviour Checklist; the VABS-II adaptive composite score showed slightly greater improvement in younger participantsPositiveYesThis study underscores the potential of digital home therapy to augment the standard of careAccording to the poststudy empirical variance, this study may be underpowered by a factor of 2; low treatment adherence; bias in recruitment of participants; bias owing to the inherent demographic and behavioral heterogeneity of patients; second posttest appointments were not available for control participants before crossing over into treatment
Wang et al [28], 2019AI: 29.1% versus control: 20.3%AI: 0.45 versus control: 0.29 (ORq 1.995, 95% CI 1.532-2.544); AI: 0.97 versus control: 0.51; AI: 0.53 versus control: 0.31; false positive rate of AI: 0.075 per colonoscopy; false negative rate of AI: not mentionedPositiveNoIn a low prevalent ADRr population, an automatic polyp detection system during colonoscopy resulted in a significant increase in the number of diminutive adenomas detected as well as an increase in the rate of hyperplastic polypsEndoscopists were not blinded; lack of external validity; despite low false positive rates, potential distraction during the procedure could also be caused; fatigue level of participating endoscopists were not controlled; inadequate sample size of colonoscopies performed by junior endoscopists; only Olympus colonoscopy equipment was used
Wu et al [29], 2019AI: 5.86% versus control: 22.46%AI: 5.03 minutes versus control: 4.24 minutes; AI: 71.87% versus control: 79.14%; AI: 90.64% versus control: 79.14%; AI: 92.91% versus control: 79.14%; percentage of patients being ignored in majority gastric sites were significantly lower than controlPositiveNoWISENSE greatly reduced blind spot rate, increased inspection time, and improved the completeness of photo documentationOnly Olympus and Fujifilm endoscopes were used in this trial; the withdrawal time in this trial was generally less than recommended 7 minutes of EGDs in the guideline
Pavel et al [30], 2020Diagnostic accuracy (sensitivity, specificity, and false detection rate) for recognition of a neonate with seizures were not significantly different between the 2 groups; sensitivity of seizure hours—AI: 66% versus control: 45.3%; false detection rate of seizure hours was not mentionedNo significant differences found in seizure characteristics; AI: 37.5% versus control: 31.6%; difference 5.9%NegativeNoIn conclusion, this clinical investigation was the first to assess the performance of a machine learning algorithm for neonatal seizure detection in real time and in the real-world setting of busy neonatal ICUs throughout EuropeExcluded seizures with a duration of <30 seconds from both groups; analysis was done using seizure hour instead of looking at each individual seizure
Alfonsi et al [31], 2020Absolute error at 3-month follow-up—AI: 27.45% (10.90%) versus control: 38.00% (14.74%); error>10 g at 3-month follow-up—AI: 21.43% (16.82%) versus control: 32.27% (16.31%)No significant difference between groups A and B in terms of accuracy, procedural safety, time for trocar placement, and patient radiation exposure (dose area product and fluoroscopy time)PositiveNoThe data suggest that use of iSpy is associated with improved carbohydrate counting and that usability and acceptability of the app is quite positiveSingle tertiary pediatric center only; the number of foods recognized by iSpy is not all encompassing; detailed information about other factors that can influence care such as education level, socioeconomic status data, family dynamics, or details of treatment regimen were not acquired; text reminders to the control participants was not provided
Auloge et al [32], 2020Group A technical feasibility was 100% with successful segmentation and generation of safe or accurate trajectory in all casesNo significant difference in accuracy; no complications or unintended effects were observed in either group—AI: mean 642 (SD 210) seconds, range 300-963 versus control: mean 336 (SD 60) seconds, range 240-438; DAPt—AI: mean 182.6 (SD 106.7) mGy cm2, range 27-355 versus control: mean 367.8 (SD 184.7) mGy cm2, range 115-644; fluoroscopy time—AI: 5.2 (SD 2.6) seconds, range 1.6-8.7 versus control: mean 10.4 (SD 4.1) seconds, range 4.2-17.9PositiveYesAugmented reality or AI–guided percutaneous vertebroplasty appears feasible, accurate and safe and facilitates lower patient radiation exposure compared with standard fluoroscopic guidanceSmall sample size; surgeon bias due to inherent nonblinding; lack of power to assess differences in vertebroplasty complication rates; accuracy of final trocar position was estimated on augmented fluoroscopic images rather than CBCTu; no clinical follow-up is presented
Avari et al [33], 2020AI: 62.5% (52.1%-67.8%) versus control: 58.4% (49.6%-64.3%)No significant difference for percentage of time in euglycemia, hypoglycemia, and hyperglycemia; no episode of serious hypoglycemia; no episodes of hypoglycemia within 5 hours postprandially; case of severe hypoglycemia; AI: 0 versus control: 1; no significant difference in glycemic riskNegativeYesThe PEPPER system was safe but did not change glycemic outcomes compared with controlThe potential need for additional time required for the adaptive insulin recommender system to be effective; the algorithm is likely to be most beneficial to individuals maintaining regular work patterns rather than shift workers; the algorithm only adapts for bolus insulin and assumes that the basal insulin has been optimized; the system is dependent on meal scenarios where the user has not ingested a significant snack or taken an insulin bolus correction within 5 hours of a meal for revision
Chen et al [34], 2020Sedated C-EGD versus unsedated U-TOEv versus unsedated C-EGD: 3.42% (0.89/26) versus 21.77% (5.66/26) versus 31.23% (8.12/26), respectivelyBlind spot rate of Sedated C-EGD—AI: 3.42 versus control: 22.46; blind spot rate of unsedated U-TOE—AI: 21.77 versus control: 29.92; blind spot rate of unsedated C-EGD—AI: 31.23 versus control: 42.46; the average accuracy, sensitivity, and specificity of EN-DOANGEL in sedated C-EGD were 88.3%, 92.6%, and 90.2%, respectively; in unsedated U-TOE, were 91.3%, 84.5%, and 90.1%, respectively; and in unsedated C-EGD, were 87.8%,8 2.8%, and 87.8%, respectivelyPositiveNoIn summary, our study showed that the number of blind spots in conventional sedated EGD was the lowest compared with unseated U-TOE and unsedated EGD, and the addition of ENDOANGEL had a maximal effect on unsedated C-EGDSingle-center study; endoscopist were not blinded
Gong et al [35], 2020ITTw—AI: 16% (58/355) versus control: 8% (27/349); PPx—AI: 17% (54/224) versus control: 8% (26/318)ITT diminutive—AI: 46 (13%) versus control: 25 (7%); ITT small—AI: 4 (1%) versus control: 1 (<1%); ITT large—AI: 10 (3%) versus control: 1 (<1%); no significant differences were found comparing adenoma locations: ITT—AI: 47% (166/355) versus control: 34% (118/349); ITT diminutive—AI: 158 (45%) versus control: 114 (33%); ITT small—AI: 9 (3%) versus control: 7 (2%); ITT large—AI: 11 (3%) versus control: 3 (1%); significant different was only found in sigmoid colon—AI: 79 (22%) versus control: 48 (14%); AI: 0.18 versus control: 0.08; AI: 1.17 versus control: 0.68; AI: 6.38 minutes versus control: 4.76 minutes; no adverse and serious adverse eventsPositiveNoIn conclusion, the ENDOANGEL system is a quality improving system for colonoscopy that uses computer vision, real-time monitoring of withdrawal speed, and timing of colonoscopy intubation and withdrawal and provides reminders to endoscopists of blind spots, in addition to live tracking previously seen frames during colonoscopyAI was validated at 1 center only; the withdrawal speed was artificially divided into safe, alarm, and dangerous by assessing videos from Renmin Hospital of Wuhan University; the difference between assisted and unassisted colonoscopy for adenomas of 6-9 mm was not significant, which could be attributable to small numbers
Liu et al [36], 2020AI: 29.01% versus control: 20.91%AI: 47.07% versus control: 33.25%; AI: 1.07 versus control: 0.51; AI: 0.48 versus control: 0.29PositiveNoIn conclusion, real-time visual alarms provided by a high-performance CADey system embedded into the primary colonoscopy monitor, with nearly unnoticeable latency, have been shown to cause a significant improvement in ADR because of an increased detection of diminutive adenomas without increasing physician fatigue level during colonoscopyOpen-labeled study; the fatigue score was subjective and susceptible to factors other than the visual alarms; whether a polyp was first detected by CADe before the endoscopist was based on the operating endoscopist’s own judgment; the fact that the CADe system detected a polyp before the endoscopists does not necessarily mean that the endoscopists would have missed that lesion
Nicolae et al [37], 2020No significant difference in CTVz V100, CTV D90, and Rectum V100 at 1-month postoperative follow-upAI: mean 2.38 (SD 0.96) minutes versus control: mean 43.13 (SD 58.70) minutes; no significant difference in need and extent of modificationsPositiveYesA machine learning–based planning workflow for prostate LDRaa brachytherapy has the potential to offer significant time savings and operational efficiencies, while producing noninferior postoperative dosimetry to that of expert, conventional treatment plannersSingle-center study; examining only preoperatively planned cases
Repici et al [38], 2020AI: 54.8% versus control: 40.4%AI: 123 versus control: 97; AI: 353 out of 262 patients versus control: 243 out of 198 patients; AI: 7% versus control: 5.2%; AI: 1.07 versus control: 0.71; AI: 95.6% versus control: 98.5%; withdrawal time: not mentionedPositiveNoIn a multicenter, randomized trial, we found that including CADe in real-time colonoscopy significantly increases ADR and adenomas detected per colonoscopy without increasing withdrawal timePsychological bias could not be excluded; the equivalence in withdrawal time excludes a somewhat reduced degree of mucosal exposure in the control arm; low detectors and inexperienced or nongastroenterologist endoscopists were not involved in this study
Su et al [39], 2020AI: 28.90% versus control: 16.51% (OR 2.055, 95% CI 1.397-3.024; P<.001)AI: 38.31% versus control: 25.40%; AI: 0.367 versus control: 0.178; AI: 0.575 versus control: 0.305; AI: mean 7.03 (SD 1.01) minutes versus control: mean 5.68 (SD 1.26) minutes; AI: 87.34% versus control: 80.63%PositiveNoIn summary, AQCSab, an automatic quality control system, could be used in real time for timing, supervising withdrawal stability, evaluating BBPSac, and detecting polypSingle endoscopic center; some false prompts occurred with the AQCS; fatigue level of participating physicians was not controlled; used 4 intraprocedural quality metrics to form the AQCS, without performing preliminary testing to evaluate whether just 2 or 3 or 4 of these metrics had the same quality improvement; did not test the sole effect of colonoscopy stability; the DCNNsad were trained only on images obtained from a Pentax imaging system
Wang et al [40], 2020AI: 13.89% versus control: 40%AI: 12.98% versus control: 45.90%; no statistical differences in the miss rate of advanced adenomas and sessile serrated adenoma or polyps; no significant difference in patient miss rate; no significant difference in ADR for the first pass; no significant difference in adenoma per colonoscopy; no significant difference in polyp per colonoscopyPositiveNoThe results from this study suggest a significantly lower AMRae when a CADe technology is used compared with routine white light colonoscopy. The detection of diminutive and small adenomas with nonadvanced histology and nonpedunculated shape could be effectively improved by CADe colonoscopyAMR obtained in the tandem study cannot reflect the absolute miss rate; subjective bias in open-labeled trial; tandem colonoscopy in each patient was performed by the same endoscopist; study population was not restricted to screening-only participants according to guidelines; only skilled endoscopists were allowed to participate in this study; subjected bias may be introduced as the judgments made by the panel of 3 experts who reviewed the video record were not a gold standard as pathology
Wang et al [41], 2020AI: 165 (34%) versus sham control: 132 (28%)AI: 252 (52%) versus sham control: 176 (37%); AI: 1.04 versus sham control: 0.64; AI: 0.58 versus sham control: 0.38PositiveNoThe CADe system is a safe and effective method to increase ADR during colonoscopyPotential bias in the presence of a second senior endoscopist; bias in patient recruitment; the actual alert numbers of the sham system should have been measured in the trial to show equivalence
Wijnberge et al [42], 2020AI: median 0.10, IQR 0.01-0.43 mm Hg versus control: median 0.44, IQR 0.23-0.72 mm HgAI: 3.00, IQR 1.00-8.00 versus control: 8.00, IQR 3.50-12.00; AI: 8.00, IQR 1.33-26.00 minutes versus control: 32.67, IQR 11.50-59.67 minutes; AI: 2.8%, IQR 0.8%-6.6% versus control: 5.6%, IQR 3%-9.4%; AI: 2.0 (0.0 to 3.0) versus control: 0.0 (−1.0 to 0.0); AI: 4.0 (0.0 to 10.7) minutes versus control: −0.7 (−4.3 to 0.7) minutes; AI: 1.5% (0.0 to 3.3) versus control: −0.2% (−1.4 to 0.3)PositiveNoIn this single-center preliminary study of patients undergoing elective noncardiac surgery, the use of a machine learning–derived early warning system compared with standard care resulted in less intraoperative hypotension. Further research with larger study populations in diverse settings is needed to understand the effect on additional patient outcomes and to fully assess safety and generalizabilitySingle center only; small sample size; patient may have their own personal minimal MAP to be maintained during surgery; depth of anesthesia was not measured; the early warning system is validated only for invasive continuous blood pressure monitoring; an observer being present in the operating room may have influenced protocol adherence
Weisinger et al [43], 2021Fugl-Meyer Assessment-Upper Extremity: week 4—AI: mean 23.2 (SD 3.91) versus control: mean 9.9 (SD 3.2); week 8—AI: mean 31.5 (SD 2.97) versus control: mean 23.1 (SD 4.99)AI: 2.5 (0.18) points versus control: 1.3 (0.16) points; significance improved: Action Research Arm Test-Pinch subscale; significance improved: Box and Block Test; significance improved: NIHSSaePositiveUnknownBQ treatment significantly improves upper extremity motor function in a population with subacute ischemic stroke across multiple clinical metrics. Further studies are planned and ongoing with larger study populations and in related indicationsNil
Blomberg et al [44], 2021AI: 93.1% (296/318) versus control: 90.5% (304/336)AI: 1.72 (1.52) minutes versus control: 1.70 (1.63) minutes; AI: 64.8% versus control: 61.9%NegativeYesThis randomized clinical trial did not find any significant improvement in dispatchers’ ability to recognize cardiac arrest when supported by machine learning even though AI did surpass human recognitionNot 100% compliance with the machine learning model; the servers analyzing the phone calls had downtime, because the server was underdimensioned
Browning et al [45], 2021QIDS-SR-16af at week 8—AI: 55.9% versus control: 51.8Generalized Anxiety Disorder Assessment, 7 item version (week 8)—AI: −5.44 versus control: −6.12NegativeYesUse of a predictive algorithm to guide antidepressant treatment improves symptoms of anxiety and functional outcomes provides initial support for the use of personalized medicine approaches in the treatment of depressionThe accuracy of the predictive algorithm was modest at 57.5%; effectiveness was focused rather than efficacy, requesting but not requiring clinicians to alter treatment in response to a prediction of nonresponse; randomization occurred at the level of the patient rather than the site, and thus, the treatment as usual arm may have been influenced by behavior learned in the active arm
Jayakumar et al [46], 2021AI: mean 68.9 (SD 19.8) versus control: mean 48.8 (SD 14.5)CollaboRATE median—AI: 8 of 69 versus control: 28 of 60; number of patient-rated satisfaction scores lower than the median value of 10—AI: 9 of 69 versus control: 19 of 60; no significant difference in duration of consultation in minutes; no significant difference in TKRag rates and treatment concordancePositiveNoIn this randomized clinical trial, an AI-enabled decision aid significantly improved decision quality, level of shared decision-making, satisfaction, and physical limitations without significantly impacting consultation times, TKR rates, or treatment concordance in patients with knee osteoarthritis considering TKR. Decision aids using a personalized, data-driven approach can enhance shared decision-making in the management of knee osteoarthritisSingle-center study; surgeons were not masked; we did not assess the effect of the decision aid on patient knowledge; the typical course of a formal osteoarthritis in-clinic diagnosis possesses a general limitation in limiting the time frame over which the tool may be applied
Kamba et al [47], 2021AI first: 13.8% versus control first: 35.7%AI first: 14.2% versus control first: 40.6%; AI first: 13% versus control first: 38.5%; AI first: 64.5% versus control first: 53.6%PositiveNoThe reduction of AMR by assisting with CADe based on deep learning in a multicenter randomized controlled trialNil
Luo et al [48], 2021AI: 38.7% versus control: 34%The number of polyps detected in the control group and the research group was 80 and 105, respectively; AI: 91 versus control: 69; polyp type 0-IIa—AI: 87 versus control: 61; polyp type 0-Is—AI: 5 versus control: 8; polyp type 0-Ip—AI: 13 versus control: 11; 52 false positive result in AI group; in average, 0.35 false positive per colonoscopyPositiveNoThis study shows that an AI system based on deep learning and its real-time performance led to significant increases in colorectal PDRahSingle center study; small sample size; AI has different effects on improving the PDR among different physicians; ADR was not compared between 2 groups in this trial
Rafferty et al [49], 2021IBSai symptom score—AI: −170 versus control: −138; quality of life score—AI: 31.1 versus control: 11.8No significant difference; AI: 8.3 (4.4-13.1) versus control: 10.4 (7.4-14.0)NegativeYesResults showed that the Heali app was able to significantly increase quality of life outcomes in IBS participants over a 30-day intervention periodSmall sample size; self-reporting bias in survey may resulted owing to lack of blinding; stratification was not done; participants were not randomized to groups until study day 10, which was after the collection of baseline data; although anthropometric measures (bodyweight and height) were collected at baseline, they were not collected at the end of the trial, and it is possible that changes in body weight influenced the outcome variables; adherence may be affected by social impacts of the COVID-19 pandemic
Repici et al [50], 2021AI: 176/330, 53.3% versus control: 146/330, 44.2%AI: 41.5% versus control: 36.1%; AI: 1.98 (range 0-15) versus control: 1.61 (range: 0-17); AI: 3.3% versus control: 5.2%; AI: 1.26 (SD 1.82) versus control: 1.04 (SD 1.75); 100% in both groups after excluding patients with inadequate bowel preparation; AI: mean 815 (SD 1.6) versus control: mean 7.98 (SD 1.5)PositiveNoCADe in real-time colonoscopy significantly increases ADR and adenomas detected per colonoscopy in a nonexpert settingNo comparison of AI assistance with alternative educational interventions among inexpert endoscopists; this study design was not fit to assess the sensitivity or specificity of the device; no power calculations were done for any of our secondary outcomes
Strömblad et al [51], 2021Mean absolute error—AI: 49.5 minutes {66} versus control: 59.3 minutes {72}Mean patient wait time: overall—AI: 16.3 minutes versus control: 49.4 minutes (67.1% improvement); turnover time: overall—AI: 69.1 minutes versus control: 70.6 minutes (2% improvement); patient time in facility—AI: 148.1 versus control: 173.3 (14.5% improvement)PositiveNoImplementing machine learning–generated predictions for surgical case durations may improve case duration accuracy, presurgical resource use, and patient wait time, without increasing surgeon wait time between casesSmall sample size; prediction accuracy may be affected if the submitted procedure codes deviate significantly from the procedures that are performed; a less common occurrence were multipanel cases in which multiple surgeons from different services operated on the same patient during the same case; there was no stratification by days
Wu et al [52], 2021AI: 5.38 (SD 4.32) versus control: 9.82AI: 5.40 (SD 3.82) minutes versus control: 4.38 (SD 3.91) minutes; the median percentage of patients with blind spots at each site—AI: 21% versus control: 38.9%; per-lesion accuracy: 84.7%; sensitivity: 100%; specificity: 84.3%PositiveNoENDOANGEL was an effective and robust system to improve the quality of EGD and has the potential to detect electrocardiogram in real timeWe only conducted a feasibility analysis on real-time detection of gastric cancer based on deep learning in a clinical setting; the enrolled patients were not followed up for a long time; statisticians were not blinded
Yao et al [53], 2021In overall cohort—AI: 2.1% versus control 1.6%; among 1356 patients who had a positive result—AI: 19.5% versus control: 14.5%No significant between AI and control on disease discoveryPositiveNoAn AI algorithm run on existing electrocardiograms enabled the early diagnosis of low ejection fraction in a large cohort of patients managed in routine primary care practices. Because electrocardiography is a low-cost test that is frequently performed for a variety of purposes, the algorithm could potentially improve early diagnosis and treatment of a condition that is often asymptomatic but has effective treatments and thus reduce the disease burden in broad populationsEchocardiogram may not be ordered by clinician as nearly all the patients had insurance coverage; study was not designed to determine the long-term clinical impact; for example, heart failure hospitalizations and mortality
Brown et al [54], 2021AMR—CADe first: 20.12% versus HDWLaj first: 31.25%PDR—CADe first: 20.7% versus HDWL first: 33.71%; HPMRak—no significant difference in the hyperplastic polyp miss rate; SSLMRal—CADe first: 7.140% versus HDWL first: 42.11%; no statistically significant difference in ADR during first pass, second pass, and whole process; no statistically significant difference in PDR during first pass, second pass, and whole process; adenoma per colonoscopy during first pass—CADe first: 1.19 versus HDWL first: 0.90; no statistically significant difference during second pass and whole process; polyp per colonoscopy during first pass—CADe first: 2.0 versus HDWL first: 1.59; polyp per colonoscopy during second pass—CADe first: 0.52 versus HDWL first: 0.81; no statistically significant difference during whole process; SSLPCam during second pass—CADe first: 0.01 versus HDWL first: 0.07; no statistically significant difference during first pass whole processPositiveNoThis study showed a decrease in AMR with the use of a deep learning CADe system when compared with HDWL colonoscopy alone and a decrease in polyp and sessile serrated lesion miss rates and an increase in first-pass adenomas per colonoscopyNot powered to detect a difference in ADR; the tandem colonoscopy design limited in terms of generalizability to the real-world clinical setting; only included experienced endoscopists with a high baseline ADR at US academic medical centers; used a second monitor adjacent to the primary endoscopy monitor

aCPAP: continuous positive airway pressure.

bAI: artificial intelligence.

cICU: intensive care unit.

dLOS: length of stay.

eHGD: high-grade dysplasia.

fEAC: esophageal adenocarcinoma.

gWATS: wide-area transepithelial sampling.

hBE: Barrett\'s esophagus.

iSAP: sensor-augmented pump.

jHPI: hypotension probability indicator.

kRCT: randomized controlled trial.

lBPI: Brief Pain Inventory.

mBQ-II: Barriers Questionnaire II.

nSBP: systolic blood pressure.

oSRS-II: Social Responsiveness Scale II.

pVABS-II: Vineland Adaptive Behavioural Scales, Second edition.

qOR: odds ratio.

rADR: adenoma detection rate.

sEGD: esophagogastroduodenoscopy.

tDAP: dose–area product.

uCBCT: cone-beam computed tomography.

vU-TOE: ultrathin transoral endoscopy.

wITT: intention to treat.

xPP: per protocol.

yCADe: computer-assisted detection.

zCTV: clinical target volume.

aaLDR: low-dose rate.

abAQCS: automatic quality control system.

acBBPS: Boston bowel preparation scale.

adDCNN: deep convolutional neural networks.

aeAMR: adenoma miss rate.

afQIDS-SR-16: Quick Inventory of Depressive Symptomatology (16-Item) (Self-Report).

agTKR: total knee replacement.

ahPDR: polyp detection rate.

aiIBS: irritable bowel syndrome.

ajHDWL: high-definition white light.

akHPMR: Hyperplastic polyp miss rate.

alSSLMR: sessile serrated lesion miss rate.

amSSLPC: sessile serrated lesion per colonoscopy.

Study Limitations

The most common limitations listed by the authors among these studies were single-center study design (22/39, 56%) and small sample size (n<1000; 33/39, 85%). This limits the generalizability and statistical power of the AI-assisted tools in different studies. There were 7 studies which were underpowered because of small sample size. Of these, 5 (71%) studies included <100 participants. Another common limitation is the open-label design (15/39, 38%).

Assessment of Risk of Bias

Detailed assessment results of the risk of bias using the second version of the Cochrane risk-of-bias tool for randomized trials are reported in Table 4. On the basis of the overall risk-of-bias assessment, 20% (8/39) of the trials had a low risk of bias, 31% (12/39) trials had some concerns, and 49% (19/39) had a high risk of bias. Missing outcome data and outcome measurements were the most common risk factors.

Table 4. Quality assessment outcome based on the second version of the Cochrane risk-of-bias tool for randomized trials.
Author (publication year)Randomization processDeviations from intended interventionsMissing outcome dataMeasurement of the outcomeSelection of the reported resultOverall bias
El Solh et al [17], 2009LowLowLowLowLowLow
Shimabukuro et al [18], 2017LowLowLowLowLowLow
Labovitz et al [6], 2017Some concernsLowLowLowLowSome concerns
Gracey et al [19], 2018Some concernsHighHighHighHighHigh
Liu et al [20], 2018Some concernsSome concernsHighHighSome concernsHigh
Vennalaganti et al [21], 2018Some concernsLowLowHighLowHigh
Biester et al [22], 2019Some concernsSome concernsHighLowHighHigh
Pouska et al [23], 2019Some concernsHighLowLowLowHigh
Lin et al [24], 2019LowLowLowLowLowLow
Kamdar et al [25], 2019Some concernsSome concernsHighHighSome concernsHigh
Persell et al [26], 2020LowHighLowHighLowHigh
Voss et al [27], 2019HighSome concernsLowHighLowHigh
Wang et al [28], 2019Some concernsLowLowLowLowSome concerns
Wu et al [29], 2019Some concernsLowLowLowLowSome concerns
Pavel et al [30], 2020Some concernsLowLowLowLowSome concerns
Alfonsi et al [31], 2020Some concernsLowLowHighLowHigh
Auloge et al [32], 2020Some concernsSome concernsLowLowLowSome concerns
Avari et al [33], 2020LowSome concernsLowSome concernsSome concernsSome concerns
Chen et al [34], 2020Some concernsLowLowLowLowSome concerns
Gong et al [35], 2020LowLowLowLowLowLow
Liu et al [36], 2020Some concernsLowLowSome concernsLowSome concerns
Nicolae et al [37], 2020Some concernsSome concernsHighLowLowHigh
Repici et al [38], 2020Some concernsLowLowLowLowSome concerns
Su et al [39], 2020LowLowLowLowLowLow
Wang et al [40], 2020LowLowLowHighLowHigh
Wang et al [41], 2020LowLowLowSome concernsLowSome concerns
Wijnberge et al [42], 2020Some concernsLowLowLowLowSome concerns
Weisinger et al [43], 2021Some concernsLowHighHighLowHigh
Blomberg et al [44], 2021LowLowHighLowLowHigh
Browning et al [45], 2021LowLowLowLowLowLow
Jayakumar et al [46], 2021Some concernsLowLowHighLowHigh
Kamba et al [47], 2021Some concernsHighHighSome concernsLowHigh
Luo et al [48], 2021Some concernsLowLowLowLowSome concerns
Rafferty et al [49], 2021HighLowLowHighLowHigh
Repici et al [50], 2021Some concernsSome concernsHighHighLowHigh
Strömblad et al [51], 2021LowLowLowLowLowLow
Wu et al [52], 2021LowLowLowLowLowLow
Yao et al [53], 2021Some concernsHighHighHighLowHigh
Brown et al [54], 2021LowLowLowHighLowHigh

Principal Findings

Despite the plethora of claims for the benefits of AI in enhancing clinical outcomes, there is a paucity of robust evidence. In this systematic review, we identified only a handful of RCTs comparing AI-assisted tools with standard-of-care management in various medical conditions. Among these RCTs, two-thirds demonstrated improved primary or secondary end points compared with the standard-of-care management. However, not all of these end points are clinically relevant, that is, leading to a change in the management plan, improving the treatment results, shortening or avoiding hospital admissions, or reducing mortality. Although we acknowledge that our definition of a clinically relevant end point may be relatively narrow, we believe that the absence of such end points in the RCTs shows a clear deficit in the available evidence.

As expected, most of these studies came from economically advanced, industrialized countries, which constituted two-thirds of the RCTs included in this systematic review. China, as a single nation, accounted for one-third of the RCTs. China’s research in this area is empowered by immense amount of resources invested in AI or machine learning (ML), internet, its vast patient population, and the availability of a nationwide electronic health record for hospitalized patients [55]. The geographical distribution of these studies is important as AI or ML relies on data fed to the system. Differences in genomic, metagenomic, and even environmental factors may influence disease patterns and the presentation of diseases. Therefore, it is desirable to develop an AI or ML tool based on data collected from different ethnic groups and tested in individual regions to prove its efficacy. There is only one AI-assisted tool, EndoScreener, which uses different ethnic groups in its development and validation. It was originally developed and trained using a different data set of endoscopic images including an open-source database of endoscopic images from Spain. Subsequently, the tool was validated in 4 prospective RCTs in China and had been recently validated in a multicenter RCT in the United States, proving its effectiveness. Future studies should focus on validation of AI-assisted tools across different ethnic groups and patient populations to ensure generalizability.

More biosignal-based AI-assisted tools have been studied than clinical data–based tools in RCTs. The most widely used were endoscopic images detecting adenoma during colonoscopy. The adenoma detection algorithm appears to be easier for cross-compatibility because of the distinct difference in appearance between adenoma (or polyp) and normal mucosa [56]. There were a total of 5 different AI-assisted adenoma or polyp detection systems tested in 9 separate RCTs, all of which successfully assisted endoscopists to detect more adenomas or polyps during colonoscopy. However, only one study successfully showed that the AI-assisted adenoma detection system could improve adenoma detection of all sizes. Other studies could only show improvement in diminutive adenoma (<5 mm) or small adenoma (<10 mm) detection [39]. Advanced adenoma or colorectal cancer detection was not improved by the AI-assisted adenoma detection system used in these studies. The US Multi-Society Task Force on Colorectal Cancer [57] suggested that patients with 1 to 2 nonadvanced adenoma sized <10 mm are at low risk and could have their surveillance colonoscopy in 7 to 10 years. The value of improvement in diminutive or small adenoma detection is uncertain. Among all studies, there was only one reported long-term outcome, that is, in-hospital mortality. Future studies should emphasize on the impact of AI-assisted tools on the long-term clinical end points.

Classical prediction models are typically clinical risk scores derived from regression-based statistical models, which could be considered an ML model that has been modified for clinical use. Ideally, RCTs should be designed with a control arm (usual clinical care), a “standard-of-care” clinical risk score arm, and a novel AI-assisted tool arm. However, given the expense and effort of a clinical trial, the SPIRIT-AI (Standard Protocol Items: Recommendations for Interventional Trials-Artificial Intelligence) extension guidelines clearly state the importance of pre-existing evidence for AI intervention, with evidence that the AI-assisted tool produces better performance compared with the standard of care [58]. Although none of the RCTs found in this systematic review used a multi-arm design, there have been well-designed studies where more “complex” ML approaches have outperformed regression-derived clinical risk scores on external validation [7,59,60].

Conclusions and Recommendations

The findings of this systematic review are by no means to discourage the use of AI in medicine. AI or ML can detect signals in an immense data pool to develop algorithms for clinical decision. Unlike humans, AI or ML can process enormous quantities of data, perform consistently, and constantly improve its performance by learning from new data. However, for AI or ML to be implemented in daily clinical practice, assisting clinicians in making important decisions, proof-of-concept evidence is not sufficient. AI-assisted tools must demonstrate unequivocal improvement in clinically relevant outcomes in properly designed randomized controlled clinical trials in which AI-assisted management is compared with standard-of-care practice. Researchers should not only focus on demonstrating the robustness of the AI algorithm in concept studies but also on translating from code to bedside by conducting RCTs in real-life clinical settings. From our systematic review, automated polyp detection is the most widely implemented AI technology in clinical practice, which sets a good example of the pathway from algorithm development to the implementation of AI technology in real-life clinical practice. Another obstacle to the implementation of AI or ML in daily clinical practice is the regulation of these technologies [8]. To grant approval from regulatory bodies, scientific evidence is required to support the safety and effectiveness of an AI-assisted tool in clinical practice. The framework for AI health care product development highlighted that RCTs are often recommended to provide strong evidence to validate the clinical efficacy and safety of an AI-assisted tool in real-world settings [61]. More RCTs of AI-assisted tools integrated into clinical practice are required to advance the role of AI or ML in medicine. We should also test how machine intelligence and human intelligence can work together on personalized management of patients.

Acknowledgments

Author DS is the co-corresponding author of this manuscript and can be reached by email at dennis.shung@yale.edu.

Data Availability

The full search strategy is provided in Multimedia Appendix 1. Additional data are available on request.

Authors' Contributions

JJYS developed the concept of the systematic review. TYTL, MFKC, YLM, KML, and JJYS contributed to the development of the study protocol. YLM and KML refined the search strategy and searched for articles. TYTL and MFKC performed study selection, data extraction, data verification, and critical appraisal. JJYS gave an independent view in case of any discrepancies. TYTL drafted the manuscript. DS and JJYS critically revised the manuscript for intellectually important content. All authors had full access to all the data presented in this manuscript and approved the final manuscript.

Conflicts of Interest

None declared.

Multimedia Appendix 1

Full search strategy.

DOCX File , 15 KB

Multimedia Appendix 2

Study design and artificial intelligence (AI)–assisted tools characteristics.

DOCX File , 28 KB

  1. McCarthy J, Minsky ML, Rochester N, Shannon CE. A proposal for the Dartmouth summer research project on artificial intelligence, August 31, 1955. AI Magazine 2006 Dec 15;27(4):12 [FREE Full text] [CrossRef]
  2. Hamamoto R. Application of artificial intelligence for medical research. Biomolecules 2021 Jan 12;11(1):90 [FREE Full text] [CrossRef] [Medline]
  3. Shung DL, Sung JJ. Challenges of developing artificial intelligence-assisted tools for clinical medicine. J Gastroenterol Hepatol 2021 Feb;36(2):295-298. [CrossRef] [Medline]
  4. Sung JJ, Stewart CL, Freedman B. Artificial intelligence in health care: preparing for the fifth Industrial Revolution. Med J Aust 2020 Sep;213(6):253-5.e1. [CrossRef] [Medline]
  5. Brown JM, Campbell JP, Beers A, Chang K, Ostmo S, Chan RV, Imaging and Informatics in Retinopathy of Prematurity (i-ROP) Research Consortium. Automated diagnosis of plus disease in retinopathy of prematurity using deep convolutional neural networks. JAMA Ophthalmol 2018 Jul 01;136(7):803-810 [FREE Full text] [CrossRef] [Medline]
  6. Labovitz DL, Shafner L, Reyes Gil M, Virmani D, Hanina A. Using artificial intelligence to reduce the risk of nonadherence in patients on anticoagulation therapy. Stroke 2017 May;48(5):1416-1419 [FREE Full text] [CrossRef] [Medline]
  7. Shung DL, Au B, Taylor RA, Tay JK, Laursen SB, Stanley AJ, et al. Validation of a machine learning model that outperforms clinical risk scoring systems for upper gastrointestinal bleeding. Gastroenterology 2020 Jan;158(1):160-167 [FREE Full text] [CrossRef] [Medline]
  8. Benjamens S, Dhunnoo P, Meskó B. The state of artificial intelligence-based FDA-approved medical devices and algorithms: an online database. NPJ Digit Med 2020 Sep 11;3:118 [FREE Full text] [CrossRef] [Medline]
  9. Hassan C, Spadaccini M, Iannone A, Maselli R, Jovani M, Chandrasekar VT, et al. Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis. Gastrointest Endosc 2021 Jan;93(1):77-85.e6. [CrossRef] [Medline]
  10. Batchu S, Liu F, Amireh A, Waller J, Umair M. A review of applications of machine learning in mammography and future challenges. Oncology 2021;99(8):483-490 [FREE Full text] [CrossRef] [Medline]
  11. Yeo M, Tahayori B, Kok HK, Maingard J, Kutaiba N, Russell J, et al. Review of deep learning algorithms for the automatic detection of intracranial hemorrhages on computed tomography head imaging. J Neurointerv Surg 2021 Apr;13(4):369-378. [CrossRef] [Medline]
  12. Zhu T, Li K, Herrero P, Georgiou P. Deep learning for diabetes: a systematic review. IEEE J Biomed Health Inform 2021 Jul;25(7):2744-2757. [CrossRef] [Medline]
  13. Yin J, Ngiam KY, Teo HH. Role of artificial intelligence applications in real-life clinical practice: systematic review. J Med Internet Res 2021 Apr 22;23(4):e25759 [FREE Full text] [CrossRef] [Medline]
  14. Sackett D. Evidence-based medicine. Lancet 1995 Oct 28;346(8983):1171. [Medline]
  15. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 2021 Mar 29;372:n71 [FREE Full text] [CrossRef] [Medline]
  16. Sterne JA, Savović J, Page MJ, Elbers RG, Blencowe NS, Boutron I, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ 2019 Aug 28;366:l4898. [CrossRef] [Medline]
  17. El Solh A, Akinnusi M, Patel A, Bhat A, TenBrock R. Predicting optimal CPAP by neural network reduces titration failure: a randomized study. Sleep Breath 2009 Nov;13(4):325-330. [CrossRef] [Medline]
  18. Shimabukuro DW, Barton CW, Feldman MD, Mataraso SJ, Das R. Effect of a machine learning-based severe sepsis prediction algorithm on patient survival and hospital length of stay: a randomised clinical trial. BMJ Open Respir Res 2017 Nov 9;4(1):e000234 [FREE Full text] [CrossRef] [Medline]
  19. Gracey B, Jones CA, Cho D, Conner S, Greene E. Improving medication adherence by better targeting interventions using artificial intelligence - a randomized control study. Value Health 2018 May;21:S76. [CrossRef]
  20. Liu X. A0069 Evaluating the impact of an integrated computer-based decision support with person-centered analytics for the management of hypertension. J Hypertension 2018 Oct;36:e2. [CrossRef]
  21. Vennalaganti PR, Kaul V, Wang KK, Falk GW, Shaheen NJ, Infantolino A, et al. Increased detection of Barrett's esophagus-associated neoplasia using wide-area trans-epithelial sampling: a multicenter, prospective, randomized trial. Gastrointest Endosc 2018 Feb;87(2):348-355. [CrossRef] [Medline]
  22. Biester T, Nir J, Remus K, Farfel A, Muller I, Biester S, et al. DREAM5: an open-label, randomized, cross-over study to evaluate the safety and efficacy of day and night closed-loop control by comparing the MD-Logic automated insulin delivery system to sensor augmented pump therapy in patients with type 1 diabetes at home. Diabetes Obes Metab 2019 Apr;21(4):822-828. [CrossRef] [Medline]
  23. Pouska J, Cerveny V, Zatloukal J, Kletecka J, Benes J. The use of HPI (Hypotension probability indicator) during major intracranial surgery; preliminary results of a prospective randomized trial. Intensive Care Med Exp 2019;7(Suppl 3):001525.
  24. Lin H, Li R, Liu Z, Chen J, Yang Y, Chen H, et al. Diagnostic efficacy and therapeutic decision-making capacity of an artificial intelligence platform for childhood cataracts in eye clinics: a multicentre randomized controlled trial. EClinicalMedicine 2019 Mar 17;9:52-59 [FREE Full text] [CrossRef] [Medline]
  25. Kamdar M, Centi AJ, Agboola S, Fischer N, Rinaldi S, Strand JJ, et al. A randomized controlled trial of a novel artificial intelligence-based smartphone application to optimize the management of cancer-related pain. J Clin Oncol 2019 May 20;37(15_suppl):11514. [CrossRef]
  26. Persell SD, Peprah YA, Lipiszko D, Lee JY, Li JJ, Ciolino JD, et al. Effect of home blood pressure monitoring via a smartphone hypertension coaching application or tracking application on adults with uncontrolled hypertension: a randomized clinical trial. JAMA Netw Open 2020 Mar 02;3(3):e200255 [FREE Full text] [CrossRef] [Medline]
  27. Voss C, Schwartz J, Daniels J, Kline A, Haber N, Washington P, et al. Effect of wearable digital intervention for improving socialization in children with autism spectrum disorder: a randomized clinical trial. JAMA Pediatr 2019 May 01;173(5):446-454 [FREE Full text] [CrossRef] [Medline]
  28. Wang P, Berzin TM, Glissen Brown JR, Bharadwaj S, Becq A, Xiao X, et al. Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study. Gut 2019 Oct;68(10):1813-1819 [FREE Full text] [CrossRef] [Medline]
  29. Wu L, Zhang J, Zhou W, An P, Shen L, Liu J, et al. Randomised controlled trial of WISENSE, a real-time quality improving system for monitoring blind spots during esophagogastroduodenoscopy. Gut 2019 Dec;68(12):2161-2169 [FREE Full text] [CrossRef] [Medline]
  30. Pavel AM, Rennie JM, de Vries LS, Blennow M, Foran A, Shah DK, et al. A machine-learning algorithm for neonatal seizure recognition: a multicentre, randomised, controlled trial. Lancet Child Adolesc Health 2020 Oct;4(10):740-749 [FREE Full text] [CrossRef] [Medline]
  31. Alfonsi JE, Choi EE, Arshad T, Sammott SA, Pais V, Nguyen C, et al. Carbohydrate counting app using image recognition for youth with type 1 diabetes: pilot randomized control trial. JMIR Mhealth Uhealth 2020 Oct 28;8(10):e22074 [FREE Full text] [CrossRef] [Medline]
  32. Auloge P, Cazzato RL, Ramamurthy N, de Marini P, Rousseau C, Garnon J, et al. Augmented reality and artificial intelligence-based navigation during percutaneous vertebroplasty: a pilot randomised clinical trial. Eur Spine J 2020 Jul;29(7):1580-1589. [CrossRef] [Medline]
  33. Avari P, Leal Y, Herrero P, Wos M, Jugnee N, Arnoriaga-Rodríguez M, et al. Safety and feasibility of the PEPPER adaptive bolus advisor and safety system: a randomized control study. Diabetes Technol Ther 2021 Mar;23(3):175-186. [CrossRef] [Medline]
  34. Chen D, Wu L, Li Y, Zhang J, Liu J, Huang L, et al. Comparing blind spots of unsedated ultrafine, sedated, and unsedated conventional gastroscopy with and without artificial intelligence: a prospective, single-blind, 3-parallel-group, randomized, single-center trial. Gastrointest Endosc 2020 Feb;91(2):332-9.e3. [CrossRef] [Medline]
  35. Gong D, Wu L, Zhang J, Mu G, Shen L, Liu J, et al. Detection of colorectal adenomas with a real-time computer-aided system (ENDOANGEL): a randomised controlled study. Lancet Gastroenterol Hepatol 2020 Apr;5(4):352-361. [CrossRef] [Medline]
  36. Liu P, Wang P, Glissen Brown JR, Berzin TM, Zhou G, Liu W, et al. The single-monitor trial: an embedded CADe system increased adenoma detection during colonoscopy: a prospective randomized study. Therap Adv Gastroenterol 2020;13:1756284820979165 [FREE Full text] [CrossRef] [Medline]
  37. Nicolae A, Semple M, Lu L, Smith M, Chung H, Loblaw A, et al. Conventional vs machine learning-based treatment planning in prostate brachytherapy: results of a Phase I randomized controlled trial. Brachytherapy 2020;19(4):470-476 [FREE Full text] [CrossRef] [Medline]
  38. Repici A, Badalamenti M, Maselli R, Correale L, Radaelli F, Rondonotti E, et al. Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial. Gastroenterology 2020 Aug;159(2):512-20.e7. [CrossRef] [Medline]
  39. Su JR, Li Z, Shao XJ, Ji CR, Ji R, Zhou RC, et al. Impact of a real-time automatic quality control system on colorectal polyp and adenoma detection: a prospective randomized controlled study (with videos). Gastrointest Endosc 2020 Feb;91(2):415-24.e4. [CrossRef] [Medline]
  40. Wang P, Liu P, Glissen Brown JR, Berzin TM, Zhou G, Lei S, et al. Lower adenoma miss rate of computer-aided detection-assisted colonoscopy vs routine white-light colonoscopy in a prospective tandem study. Gastroenterology 2020 Oct;159(4):1252-61.e5. [CrossRef] [Medline]
  41. Wang P, Liu X, Berzin TM, Glissen Brown JR, Liu P, Zhou C, et al. Effect of a deep-learning computer-aided detection system on adenoma detection during colonoscopy (CADe-DB trial): a double-blind randomised study. Lancet Gastroenterol Hepatol 2020 Apr;5(4):343-351. [CrossRef] [Medline]
  42. Wijnberge M, Geerts BF, Hol L, Lemmers N, Mulder MP, Berge P, et al. Effect of a machine learning-derived early warning system for intraoperative hypotension vs standard care on depth and duration of intraoperative hypotension during elective noncardiac surgery: the HYPE randomized clinical trial. JAMA 2020 Mar 17;323(11):1052-1060 [FREE Full text] [CrossRef] [Medline]
  43. Weisinger BS, Bornstein NM, Shohami E, Segal Y, Alter A, Lifshitz A, et al. Abstract P194: Artificial intelligence-powered non-invasive and frequency-tuned electromagnetic field therapy improves upper extremity motor function in sub-acute stroke patients: a pilot randomized controlled trial. Stroke 2021 Mar;52(Suppl_1):194. [CrossRef]
  44. Blomberg SN, Christensen HC, Lippert F, Ersbøll AK, Torp-Petersen C, Sayre MR, et al. Effect of machine learning on dispatcher recognition of out-of-hospital cardiac arrest during calls to emergency medical services: a randomized clinical trial. JAMA Netw Open 2021 Jan 04;4(1):e2032320 [FREE Full text] [CrossRef] [Medline]
  45. Browning M, Bilderbeck AC, Dias R, Dourish CT, Kingslake J, Deckert J, et al. The clinical effectiveness of using a predictive algorithm to guide antidepressant treatment in primary care (PReDicT): an open-label, randomised controlled trial. Neuropsychopharmacology 2021 Jun;46(7):1307-1314 [FREE Full text] [CrossRef] [Medline]
  46. Jayakumar P, Moore MG, Furlough KA, Uhler LM, Andrawis JP, Koenig KM, et al. Comparison of an artificial intelligence-enabled patient decision aid vs educational material on decision quality, shared decision-making, patient experience, and functional outcomes in adults with knee osteoarthritis: a randomized clinical trial. JAMA Netw Open 2021 Feb 01;4(2):e2037107 [FREE Full text] [CrossRef] [Medline]
  47. Kamba S, Tamai N, Horiuchi H, Matsui H, Kobayashi M, Ego M, et al. ID: 3519580 A multicentre randomized controlled trial to verify the reducibility of adenoma miss rate of colonoscopy assisted with artificial intelligence based software. Gastrointest Endosc 2021 Jun 1;93(6):AB195. [CrossRef]
  48. Luo Y, Zhang Y, Liu M, Lai Y, Liu P, Wang Z, et al. Artificial intelligence-assisted colonoscopy for detection of colon polyps: a prospective, randomized cohort study. J Gastrointest Surg 2021 Aug;25(8):2011-2018 [FREE Full text] [CrossRef] [Medline]
  49. Rafferty AJ, Hall R, Johnston CS. A novel mobile app (Heali) for disease treatment in participants with irritable bowel syndrome: randomized controlled pilot trial. J Med Internet Res 2021 Mar 02;23(3):e24134 [FREE Full text] [CrossRef] [Medline]
  50. Repici A, Spadaccini M, Antonelli G, Correale L, Maselli R, Galtieri PA, et al. Artificial intelligence and colonoscopy experience: lessons from two randomised trials. Gut 2022 Apr;71(4):757-765. [CrossRef] [Medline]
  51. Strömblad CT, Baxter-King RG, Meisami A, Yee SJ, Levine MR, Ostrovsky A, et al. Effect of a predictive model on planned surgical duration accuracy, patient wait time, and use of presurgical resources: a randomized clinical trial. JAMA Surg 2021 Apr 01;156(4):315-321 [FREE Full text] [CrossRef] [Medline]
  52. Wu L, He X, Liu M, Xie H, An P, Zhang J, et al. Evaluation of the effects of an artificial intelligence system on endoscopy quality and preliminary testing of its performance in detecting early gastric cancer: a randomized controlled trial. Endoscopy 2021 Dec;53(12):1199-1207. [CrossRef] [Medline]
  53. Yao X, Rushlow DR, Inselman JW, McCoy RG, Thacher TD, Behnken EM, et al. Artificial intelligence-enabled electrocardiograms for identification of patients with low ejection fraction: a pragmatic, randomized clinical trial. Nat Med 2021 May;27(5):815-819. [CrossRef] [Medline]
  54. Glissen Brown JR, Mansour NM, Wang P, Chuchuca MA, Minchenberg SB, Chandnani M, et al. Deep learning computer-aided polyp detection reduces adenoma miss rate: a United States multi-center randomized tandem colonoscopy study (CADeT-CS trial). Clin Gastroenterol Hepatol 2022 Jul;20(7):1499-507.e4 [FREE Full text] [CrossRef] [Medline]
  55. Zhang L, Long J, Jiang W, Shi Y, He X, Zhou Z, et al. Trends in chronic kidney disease in China. N Engl J Med 2016 Sep 01;375(9):905-906. [CrossRef] [Medline]
  56. Samarasena JB. Guns, germs, and steel…and artificial intelligence. Gastrointest Endosc 2021 Jan;93(1):99-101. [CrossRef] [Medline]
  57. Gupta S, Lieberman D, Anderson JC, Burke CA, Dominitz JA, Kaltenbach T, et al. Recommendations for follow-up after colonoscopy and polypectomy: a consensus update by the US multi-society task force on colorectal cancer. Am J Gastroenterol 2020 Mar;115(3):415-434 [FREE Full text] [CrossRef] [Medline]
  58. Cruz Rivera S, Liu X, Chan AW, Denniston AK, Calvert MJ, SPIRIT-AI and CONSORT-AI Working Group. Guidelines for clinical trial protocols for interventions involving artificial intelligence: the SPIRIT-AI extension. Lancet Digit Health 2020 Oct;2(10):e549-e560 [FREE Full text] [CrossRef] [Medline]
  59. Kakadiaris IA, Vrigkas M, Yen AA, Kuznetsova T, Budoff M, Naghavi M. Machine learning outperforms ACC / AHA CVD risk calculator in MESA. J Am Heart Assoc 2018 Nov 20;7(22):e009476 [FREE Full text] [CrossRef] [Medline]
  60. Brown SM, Jones J, Kuttler KG, Keddington RK, Allen TL, Haug P. Prospective evaluation of an automated method to identify patients with severe sepsis or septic shock in the emergency department. BMC Emerg Med 2016 Aug 22;16(1):31 [FREE Full text] [CrossRef] [Medline]
  61. Higgins D, Madai VI. From bit to bedside: a practical framework for artificial intelligence product development in healthcare. Adv Intell Syst 2020 Jul 02;2(10):2000052. [CrossRef]


AI: artificial intelligence
ML: machine learning
PRISMA: Preferred Reporting Items for Systematic Reviews and Meta-Analyses
RCT: randomized controlled trial
SPIRIT-AI: Standard Protocol Items: Recommendations for Interventional Trials-Artificial Intelligence


Edited by G Eysenbach; submitted 10.02.22; peer-reviewed by T Jamieson, B Puladi, SY Shin; comments to author 19.05.22; revised version received 13.06.22; accepted 29.07.22; published 25.08.22

Copyright

©Thomas Y T Lam, Max F K Cheung, Yasmin L Munro, Kong Meng Lim, Dennis Shung, Joseph J Y Sung. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 25.08.2022.

This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included.