Original Paper
Abstract
Background: Continuous positive airway pressure (CPAP) is an effective treatment for obstructive sleep apnea (OSA), but treatment compliance is often unsatisfactory.
Objective: The aim of this study was to assess the effectiveness and cost-effectiveness of an intelligent monitoring system for improving CPAP compliance.
Methods: This is a prospective, open label, parallel, randomized controlled trial including 60 newly diagnosed patients with OSA requiring CPAP (Apnea–Hypopnea Index [AHI] >15) from Lleida, Spain. Participants were randomized (1:1) to standard management or the MiSAOS intelligent monitoring system, involving (1) early compliance detection, thus providing measures of patient’s CPAP compliance from the very first days of usage; (2) machine learning–based prediction of midterm future CPAP compliance; and (3) rule-based recommendations for the patient (app) and care team. Clinical and anthropometric variables, daytime sleepiness, and quality of life were recorded at baseline and after 6 months, together with patient’s compliance, satisfaction, and health care costs.
Results: Randomized patients had a mean age of 57 (SD 11) years, mean AHI of 50 (SD 27), and 13% (8/60) were women. Patients in the intervention arm had a mean (95% CI) of 1.14 (0.04-2.23) hours/day higher adjusted CPAP compliance than controls (P=.047). Patients’ satisfaction was excellent in both arms, and up to 88% (15/17) of intervention patients reported willingness to keep using the MiSAOS app in the future. No significant differences were found in costs (control: mean €90.2 (SD 53.14) (US $105.76 [SD 62.31]); intervention: mean €96.2 (SD 62.13) (US $112.70 [SD 72.85]); P=.70; €1=US $1.17 was considered throughout). Overall costs combined with results on compliance demonstrated cost-effectiveness in a bootstrap-based simulation analysis.
Conclusions: A machine learning–based intelligent monitoring system increased daily compliance, reported excellent patient satisfaction similar to that reported in usual care, and did not incur in a substantial increase in costs, thus proving cost-effectiveness. This study supports the implementation of intelligent eHealth frameworks for the management of patients with CPAP-treated OSA and confirms the value of patients’ empowerment in the management of chronic diseases.
Trial Registration: ClinicalTrials.gov NCT03116958; https://clinicaltrials.gov/ct2/show/NCT03116958
doi:10.2196/24072
Keywords
Introduction
Obstructive sleep apnea (OSA) is the most prevalent sleep-disordered breathing condition, affecting 15%-30% of adults in Western countries [
]. It is characterized by repetitive episodes of airways collapse during sleep, causing sleep fragmentation, intermittent hypoxia, and daytime somnolence. OSA has been associated with increased morbidity and mortality, and has an impact on quality of life [ ]. In this sense, increased inflammation, oxidative stress, sympathetic activation, and hypercoagulability are the main mechanisms associating OSA with hypertension; cancer; and cardiovascular, cerebrovascular, and metabolic diseases [ ].Nocturnal continuous positive airway pressure (CPAP), preventing upper airway collapse during sleep, is the treatment of choice for patients with symptomatic OSA [
]. A satisfactory CPAP compliance (≥4 hours/day) improves daytime sleepiness and overall quality of life; reduces OSA severity markers, such as the Apnea–Hypopnea Index (AHI); moderately decreases arterial blood pressure (BP), mainly in patients with resistant hypertension [ , ]; and contributes to preventing the onset of newly diagnosed hypertension [ ]. Compliance is, therefore, essential for the efficacy of CPAP treatment and its optimization is an important aspect of patient management. However, up to one-third of patients underuse or even discontinue CPAP [ - ], mostly because of treatment-related side effects such as machine noise, pressure intolerance, mask displacement, or claustrophobia [ ]. In this sense, issues hampering CPAP compliance during the first months of treatment are likely to have a significant impact on long-term CPAP compliance [ ]. Therefore, there is a need to implement effective strategies for the promotion of CPAP compliance, especially during the first months of treatment.So far, interventions tackling CPAP compliance, including novel educational and supportive or therapeutic strategies, have reported low to moderate evidence of success [
, ]. By contrast, when these strategies are wrapped up in comprehensive packages making use of information and communication technologies (eHealth) and targeting the initial months after CPAP prescription, the potential for success can be significantly enhanced [ - ]. In this scenario, and within the frame of the MiSAOS project, an internet of things–based intelligent monitoring system relying on machine learning [ ] was developed in Catalonia, Spain, with a fourfold goal: (1) predicting patient’s potential early CPAP compliance; (2) providing real-time monitoring of patient’s CPAP compliance, informing both the patient and the care team, and granting decision support; (3) empowering the patient by means of feedback and recommendations; and (4) reducing patient’s overall management costs. This study compares, in terms of effectiveness and cost-effectiveness, the MiSAOS intelligent monitoring system model, based on early compliance detection, compliance prediction, and rule-based recommendations, with the usual care provided to patients using CPAP in the region of Lleida, Catalonia.Methods
Study Design
This is a prospective, open label, parallel, randomized controlled trial comparing the MiSAOS management model with care as usual for a duration of 6 months after CPAP prescription (ClinicalTrials.gov NCT03116958). The study was conducted from November 2016 to December 2017 in Lleida, Catalonia.
shows the CONSORT checklist of this study.Target Population
Eligible population included patients with OSA (AHI ≥15) being newly diagnosed in the sleep unit of University Hospital Santa Maria, Lleida, and requiring CPAP treatment according to the Spanish Respiratory Society (SEPAR) guidelines [
]. The specific eligibility criteria were aged over 18 years; having a sufficient competence in the use of smartphones; not having been previously treated with CPAP; not having impaired lung function (overlap syndrome, obesity hypoventilation syndrome, and restrictive disorders), severe heart failure, severe chronic pathologies, psychiatric disorders, or periodic leg movements or other dyssomnias or parasomnias; and not being pregnant.Sample Size
Accepting an α risk of .05 and a β risk of .2 in a 2-sided test, 29 patients per study arm were needed to recognize as statistically significant a difference in compliance greater than or equal to 1 hour/day. The common SD was assumed to be 1.35, based on previous research of the group.
Recruitment, Randomization, and Intervention
Patients were recruited in the sleep unit and randomized (1:1) to receive 6 months of either MiSAOS or usual care management. Patients in the usual care arm were managed according to the SEPAR guidelines [
]. Randomization was based on a permuted-block design with a computer random number generator and a fixed block size of 4. Patients were fitted with a mask and given a CPAP device (AirSense 10; ResMed) and a leaflet explaining how to use it. A short training session on how to use the CPAP device was also given to patients and partners in the sleep unit by a trained nurse with experience in the follow-up of CPAP-treated patients. This included a practical demonstration of how to put on the mask, and the correct management and cleaning of the tubes, mask, and humidifier. Information on how to turn the CPAP device on and off was provided by the homecare provider at the time of machine delivery. According to SEPAR recommendations, patients were visited after 1 month of treatment by the specialist nurse at the sleep unit. Information about CPAP, compliance (use of CPAP for ≥4 hours/day), residual respiratory events, and leaks was downloaded from the device. CPAP-related side effects, CPAP machine care and maintenance actions (ie, changes of mask), and the number of required additional visits or calls were recorded by the nurse.Similarly, patients in the MiSAOS arm were fitted with a mask, a CPAP device (AirSense 10; ResMed), and given a leaflet explaining its use. Patients received the same training sessions from the same personnel as in the usual care arm. However, these patients’ CPAP devices were equipped with mobile 2G (global systems for mobile/general packet radio service [GSM/GPRS]) technology capable of sending daily information on CPAP compliance, CPAPs, mask leaks, and residual respiratory events to the MiSAOS–Oxigen salud web database. In addition, patients in the MiSAOS arm had access to an integrated platform including a website [
] and a mobile app (MiSAOS; available for both Android and iOS), benefitting from continuous monitoring and personalized feedback. Sample screenshots of the MiSAOS app showing its main functionalities and features are presented in . Similarly, sample screenshots of the MiSAOS website showing some of its functionalities and features are presented in . Hospital lung specialists managing these patients and the CPAP provider (Oxigen salud) also had access to the MiSAOS website that provided relevant information and decision support according to the specific role and access rights of each professional user. Finally, the cloud-based MiSAOS platform connected all the devices for data exchange and hosted an intelligent monitoring system, based on machine learning, capable of predicting the expected compliance with the therapy by a given patient, thus providing adequate feedback and proposing personalized interventions to increase compliance [ , ]. Predictions of patient’s midterm compliance were based on patient’s characteristics, such as anthropometric data and clinical information, and early compliance data. Examples of the needed information and provided outcome can be found in . Based on these predictions, patients were classified into 2 groups: low compliance and medium/high compliance, and recommendations were provided based on these classes. In brief, recommendations included warnings and exhortation to do better in case of low compliance, or positive reinforcement messages in case of good compliance, highlighting the key areas to be improved regardless of the compliance. This platform was also used for the monitoring of patient compliance, prompting actions when compliance was too low.Data Collection
Baseline information was collected by sleep unit personnel during recruitment, regardless of the study arm. This included age; gender; socioeconomic level; Epworth Sleepiness Scale (ESS) score; EuroQoL-5D quality of life (EQ-5D); lifestyle habits (tobacco and alcohol consumption); comorbidities; use of medications; weight; height; BMI; neck, waist, and hip circumference; and BP. Variables of the sleep study were also recorded and included registration time, sleep duration, AHI, and percentage of nighttime spent with an oxygen saturation less than 90%.
At 3 and 6 months all patients, regardless of the study arm, were visited at the sleep unit. Patients were checked about progress and compliance with therapy and any problems with their CPAP machine. During these visits we collected data on treatment compliance (number of hours/day), ESS score, OSA-related symptoms, EQ-5D, BP, and anthropometric variables. Additionally, data on CPAP, residual respiratory events and leaks, CPAP-related side effects (mask allergies and skin irritations, dry mouth, congestion, runny nose, sneezing, sinusitis, nosebleeds, and discomfort), overall satisfaction with the therapy (questionnaire), CPAP machine care and maintenance actions (ie, changes of mask), and the number of any additional visits and calls required by the patient during the follow-up were collected. Finally, costs for each component, use of services, and visits were computed based on standard prices of the CPAP provider and on Catalan Health Department official data (CVE-DOGC-A-13051031-2013) [
]. Only direct costs were considered.Statistical Analyses
A t test, or an equivalent nonparametric test, or chi-square test was used for baseline bivariate analyses, depending on variables’ characteristics. Differences in the primary and secondary outcomes between the intervention and control groups at 6 months were assessed using ordinary least-squares linear models. All models were adjusted by age, and models for secondary outcomes were further adjusted by the baseline values. A 2-sided P value and 95% CI were used. The cost-effectiveness analysis was performed using the total costs for each arm based on intervention effectiveness (CPAP treatment compliance). A probabilistic sensitivity analysis was performed using the bootstrap method, which was represented in a cost-effectiveness plan.
The primary and secondary analyses were performed on both the intention-to-treat (ITT) and per-protocol (PP) samples. The ITT sample included all the patients who were randomized. The PP sample excluded the patients who were lost during the follow-up period. Missing data were imputed using multiple imputation consisting of chained equations, for which 10 complete databases were checked. The R package “mice” was used for these calculations. All statistical analyses and data processing procedures were performed using R software, version 3.4.4 (The R Foundation).
Ethical Considerations
This study was approved by the Ethics Committee of Hospital Arnau de Vilanova (CEIC-1283) and all patients provided written informed consent. This project was registered in ClinicalTrials.gov (registration number NCT03116958).
Results
A total of 60 patients were randomized to receive either MiSAOS (intervention; n=30) or usual care (control; n=30) management, and up to 53 patients completed the study (
). Patients’ baseline characteristics in both study arms are presented in , which show that only age was statistically different among groups.shows the primary and secondary outcomes of the trial according to an ITT analysis. After 6 months, the mean (95% CI) CPAP compliance was 4.89 (4.05-5.72) hours/day in the control group and 5.79 (5.20-6.38) hours/day in the intervention group, with an adjusted difference of 1.14 (0.04-2.23; P=.047) hours/day in benefit of intervention. Furthermore, the intervention arm had a higher proportion of patients with good compliance (use of CPAP for ≥4 hours/day) than the control arm (88.5% [23/26] vs 70.4% [19/27], respectively; P=.20), although this did not achieve statistical significance. Regarding secondary outcomes, ESS, BP, and the EQ-5D visual analog scale scores improved after 6 months of CPAP treatment in both arms, although the change in systolic BP was significantly higher in patients in the control arm than in those in the intervention arm (adjusted P=.04). Results on a PP approach were similar and are shown in .
Characteristic | Control (n=30) | Intervention (n=30) | P value |
Gender (male), n (%) | 26 (87) | 26 (87) | .99 |
Age (years), mean (SD) | 58 (10) | 52 (12) | .04 |
Weight (kg), mean (SD) | 97 (19) | 101 (23) | .42 |
BMI (kg/m2), mean (SD) | 33.1 (6.4) | 34.7 (7.3) | .38 |
Systolic blood pressure (mmHg), mean (SD) | 138 (17) | 142 (20) | .42 |
Diastolic blood pressure (mmHg), median (range) | 87 (79-96) | 88 (81-95) | .74 |
Apnea–Hypopnea Index (events/hour) | 39 (25-71) | 53 (35-65) | .22 |
aData as per t test, or an equivalent nonparametric test, or chi-square test depending on variables’ characteristics.
Differences | Control (n=30), mean (SD) | Intervention (n=30), mean (SD) | Difference, mean (95% CI) | |||||
Primary outcome | ||||||||
Compliance (hours/day) | 4.89 (2.30) | 5.79 (1.60) | ||||||
Crude difference | 0.90 (–0.16 to 1.96) | |||||||
Adjusted difference | 1.14 (0.04 to 2.23) | |||||||
Secondary outcomes | ||||||||
ESSb score (0-24) | ||||||||
Baseline | 10.9 (5.35) | 11.1 (5.35) | ||||||
6 months | 4.90 (2.41) | 5.85 (3.91) | ||||||
Change | –5.98 (4.42) | –5.22 (4.78) | ||||||
Crude difference | 0.76 (–1.64 to 3.16) | |||||||
Adjusted difference | 1.05 (–0.51 to 2.61) | |||||||
Weight (kg) | ||||||||
Baseline | 97.0 (18.6) | 101 (22.5) | ||||||
6 months | 98.2 (20.2) | 100 (20.7) | ||||||
Change | 1.26 (7.86) | –0.95 (7.91) | ||||||
Crude difference | –2.21 (–6.98 to 2.56) | |||||||
Adjusted difference | –2.55 (–7.41 to 2.32) | |||||||
BMI (kg/m2) | ||||||||
Baseline | 33.3 (6.20) | 34.7 (7.17) | ||||||
6 months | 34.2 (6.80) | 34.8 (6.32) | ||||||
Change | 0.98 (3.26) | 0.14 (3.16) | ||||||
Crude difference | –0.84 (–2.95 to 1.27) | |||||||
Adjusted difference | –0.82 (–2.97 to 1.32) | |||||||
Systolic blood pressure (mmHg) | ||||||||
Baseline | 138 (17.0) | 142 (19.4) | ||||||
6 months | 131 (12.7) | 138 (17.2) | ||||||
Change | –7.02 (15.2) | –3.80 (12.7) | ||||||
Crude difference | 3.22 (–5.03 to 11.47) | |||||||
Adjusted difference | 7.81 (0.57 to 15.05) | |||||||
Diastolic blood pressure (mmHg) | ||||||||
Baseline | 87.7 (13.5) | 90.3 (12.5) | ||||||
6 months | 81.6 (8.84) | 86.8 (9.23) | ||||||
Change | –6.13 (11.4) | –3.52 (10.6) | ||||||
Crude difference | 2.61 (–4.04 to 9.27) | |||||||
Adjusted difference | 4.52 (–0.65 to 9.69) | |||||||
EQ-5Dc HUId (0-1) | ||||||||
Baseline | 0.84 (0.22) | 0.85 (0.17) | ||||||
6 months | 0.80 (0.19) | 0.86 (0.20) | ||||||
Change | –0.04 (0.17) | 0.00 (0.18) | ||||||
Crude difference | 0.05 (–0.05 to 0.15) | |||||||
Adjusted difference | 0.03 (–0.06 to 0.13) | |||||||
EQ-5D VASe (0-10) | ||||||||
Baseline | 4.93 (3.41) | 4.63 (3.55) | ||||||
6 months | 7.35 (1.71) | 8.03 (1.32) | ||||||
Change | 2.42 (2.87) | 3.40 (3.65) | ||||||
Crude difference | 0.98 (–0.72 to 2.69) | |||||||
Adjusted difference | 0.51 (–0.3 to 1.33) |
aOrdinary least-squares linear models adjusted by age and baseline value.
bESS: Epworth Sleepiness Scale.
cEQ-5D: EuroQoL-5D quality of life.
dHUI: health utility index
eVAS: visual analog scale.
Patients’ satisfaction with the management of their illness was excellent in both study groups (
). Similarly, no differences were found in the occurrence of CPAP-related side effects. Finally, all patients in the intervention group reported the MiSAOS app to be useful; 94% (16/17) of patients reported that it was easy to use, and 88% (15/17) of patients reported the willingness to continue to use it in the future ( ).Users’ satisfaction | Control (n=26) | Intervention (n=19) | P value | ||||||||||
Overall satisfaction | |||||||||||||
The follow-up I received was sufficient to manage my health and medical needs | |||||||||||||
Agrees/strongly agrees, n (%) | 26 (100) | 19 (100) | |||||||||||
Overall score (1-7), mean (SD) | 6.38 (0.80) | 6.53 (0.61) | .51 | ||||||||||
In general I am satisfied with the management of my illness | |||||||||||||
Agrees/strongly agrees, n (%) | 26 (100) | 19 (100) | |||||||||||
Overall score (1-7), mean (SD) | 6.62 (0.57) | 6.53 (0.61) | .62 | ||||||||||
My contact with the hospital was sufficient | |||||||||||||
Agrees/strongly agrees, n (%) | 26 (100) | 18 (95) | |||||||||||
Overall score (1-7), mean (SD) | 6.62 (0.64) | 6.21 (1.62) | .31 | ||||||||||
Satisfaction with MiSAOS (intervention only) (n=17) | |||||||||||||
The app was useful | |||||||||||||
Agrees/strongly agrees, n (%) | 17 (100) | ||||||||||||
Overall score (1-7), mean (SD) | 6.53 (0.72) | ||||||||||||
The app was easy to use | |||||||||||||
Agrees/strongly agrees, n (%) | 16 (94) | ||||||||||||
Overall score (1-7), mean (SD) | 6.41 (0.87) | ||||||||||||
I would like to use the app every day in the future | |||||||||||||
Agrees/strongly agrees, n (%) | 15 (88) | ||||||||||||
Overall score (1-7), mean (SD) | 6.35 (1.17) |
aThe overall satisfaction questionnaire was answered by 26 controls and 19 intervention participants. The satisfaction with MiSAOS questionnaire was answered by 17 participants.
shows the costs of the intervention, costs of contacts with the CPAP provider and health system (not including the baseline, 3-month, and 6-month visits, as all patients regardless of study arm did them), and costs of any CPAP machine care and maintenance intervention actions (ie, changes of mask) during the 6 months of follow-up. The overall mean cost per patient was €90.2 (SD 53.14) (US $105.76 [SD 62.31]) in the control group and €96.2 (SD 62.13) (US $112.70 [SD 72.85]) in the intervention group, resulting in a nonsignificant cost difference between arms (P=.70). The main differences between arms were €49.5 (US $58.04) of the intervention costs (2G [GSM/GPRS] daily data transfer and activation and maintenance costs) in the MiSAOS arm, and the €41 (US $48.07) on sleep unit visits in the usual care arm. This overall cost, combined with the results on CPAP treatment compliance (primary outcome), demonstrated cost-effectiveness in a bootstrap-based simulation analysis ( ).
Concept | Control (n=30), €a/patient, mean (SD) | Intervention (n=30), €/patient, mean (SD) | Difference, mean (95% CI) | ||||
Intervention costsb | |||||||
2G (GSMc/GPRSd) daily data transfer | 0 (0) | 41.5 (0) | –41.5 (—) | ||||
Activation and maintenance | 0 (0) | 8 (0) | –8 (—) | ||||
Follow-up costs | |||||||
Sleep unit visits and consultationse | 41 (0) | 0 (0) | 41 (—) | ||||
CPAPf provider visits and consultationsg | 9.7 (8.9) | 10.0 (10.8) | –0.33 (–5.5 to 4.8) | ||||
Changes in CPAP device componentsh | |||||||
ResMed Mirage Quattro | 12.5 (28.4) | 10.0 (32.6) | 2.5 (–13.3 to 18.3) | ||||
ResMed Mirage FX | 0.8 (4.4) | 3.2 (8.3) | –2.4 (–5.9 to 1.1) | ||||
ResMed Mirage Micro | 0 (0) | 1.1 (4.1) | –1.07 (–2.6 to 0.4) | ||||
ResMed Swift FX | 1.5 (8.2) | 4.5 (13.7) | –3 (–8.9 to 2.9) | ||||
ResMed Airfit P10 (without head-gear) | 0 (0) | 1.3 (7.3) | –1.33 (–4.1 to 1.4) | ||||
Philips Respironics Nuance gel | 0 (0) | 2.45 (13.4) | –2.45 (–7.5 to 2.6) | ||||
ResMed Airfit F10 | 15.0 (30.5) | 10.0 (25.9) | 5 (–9.6 to 19.6) | ||||
ResMed Airfit P10 (with head-gear) | 1.50 (8.22) | 0 (0) | 1.5 (–1.6 to 4.6) | ||||
SleepNet IQ | 2.20 (8.86) | 0 (0) | 2.2 (–1.1 to 5.5) | ||||
SleepNet Ascend | 0 (0) | 0.8 (4.4) | –0.8 (–2.4 to 0.8) | ||||
Philips Respironics Amara View | 5.00 (15.3) | 3.3 (18.3) | 1.66 (–7.0 to 10.4) | ||||
Philips Respironics Comfort Gel Blue | 1.00 (5.48) | 0 (0) | 1 (–1.0 to 3.0) | ||||
Total | 90.2 (53.1) | 96.2 (62.1) | –6.0 (–35.9 to 23.9) |
a€1 = US $1.17.
bEstimated costs supplied by the CPAP provider: 2G (GSM/GPRS) daily data transfer (€83 [US $97.32]/year); activation and maintenance (€16 [US $18.76]/year).
cGSM: global systems for mobile.
dGPRS: general packet radio service.
eNot including the baseline, 3-month, and 6-month visits, as all patients did them regardless of study arm. Costs based on the Catalan Institute of Health (CVE-DOGC-A-13051031-2013): sleep unit visits and consultations (€41 [US $48.07]/contact).
fCPAP: continuous positive airway pressure.
gCommercial costs supplied by the CPAP provider: CPAP provider visits and consultations (€10 [US $11.73]/contact).
hCommercial costs supplied by the CPAP provider: ResMed Mirage Quattro (€75 [US $87.94]/unit); ResMed Mirage FX (€24 [US $28.14]/unit); ResMed Mirage Micro (€16 [US $18.76]/unit); ResMed Swift FX (€45 [US $52.76]/unit); ResMed Airfit P10 (without headgear) (€40 [US $46.90]/unit); Philips Respironics Nuance gel (€73.5 [US $86.18]/unit); ResMed Airfit F10 (€75 [US $87.94]/unit); ResMed Airfit P10 (with head-gear) (€45 [US $52.76]/unit); SleepNet IQ (€22 [US $25.80]/unit); SleepNet Ascend (€24 [US $28.14]/unit); Philips Respironics Amara View (€50 [US $58.63]/unit); Philips Respironics Comfort Gel Blue (€30 [US $35.18]/unit).
Discussion
Principal Findings
This study is the first randomized controlled clinical trial assessing the effectiveness and cost-effectiveness of a machine learning–based intelligent monitoring system aiming to improve CPAP compliance in patients with OSA. The MiSAOS intelligent monitoring system, based on early compliance detection, compliance prediction, and rule-based recommendations, was compared with usual care in the region of Lleida, showing a mean increase of 1.14 hours in daily compliance with no substantial differences in direct costs and an excellent patient satisfaction. This novel management system proved to be cost-effective and thus a viable option for the management of patients with OSA treated with CPAP.
Strengths and Limitations
This study has several strengths, including the (1) use of the same CPAP devices in both study arms; (2) use of an intelligent monitoring system model, based on early compliance detection, machine learning–based compliance prediction, and rule-based recommendations; (3) inclusion of continuous patient feedback through an app; (4) measurement of a broad range of effect measures (ie, compliance, changes in symptoms, and changes in quality of life); (5) assessment of patient comfort and satisfaction; and (6) inclusion of cost and cost-effectiveness analyses. Nevertheless, there are also some limitations to be acknowledged: (1) the slight infraestimation of the required number of study participants limited the statistical power of some of the between-arm comparisons, although this did not affect the results on the primary outcome and cost-effectiveness analysis; (2) the assessment of patient satisfaction was performed using a nonvalidated questionnaire; (3) the exclusion of patients with severe chronic pathologies and other dyssomnias or parasomnias could limit the generalizability of our results, although the included patients would be the ideal target for eHealth interventions as more complex patients could require a close follow-up in the sleep units; (4) the results of cost analyses are highly dependent on the characteristics of the health care setting in which they are conducted and, thus, extrapolation of the results to different settings should be done cautiously; and (5) the follow-up period does not allow the extrapolation of results to the long term.
Comparison With Existing Literature
Patients experiencing the MiSAOS intelligent monitoring system showed a mean increase of 1.14 hours in daily CPAP compliance when compared with patients in usual care. This result is more positive than the mean (95% CI) increase of 0.54 (0.29-0.79) hours reported by Aardoom et al [
] in a 2020 meta-analysis including 18 studies with eHealth interventions. Other recent studies exploring advanced monitoring systems have shown similarly inferior results, for instance, Pépin et al [ ] reported a 0.53 hours’ increase in CPAP compliance in patients with OSA with high cardiovascular risk using a multimodal telemonitoring intervention. Interestingly, granting patients an easy access to their compliance data has shown successful results in terms of increasing patient compliance [ - ]. Therefore, the combination of an intelligent machine learning–based monitoring system with the empowerment of patients, based on access to daily compliance and personalized feedback through an app, could represent a significant step forward in the promotion of CPAP compliance.The impact of the CPAP treatment on secondary outcomes in the MiSAOS intervention was very similar to that achieved in usual care and reports in previous literature [
, ]. Sleepiness, overall quality of life, and BP improvements after 6 months of follow-up were similar in both study arms. The only difference between study arms was the significantly higher decrease in systolic BP in patients having usual care, which could be easily explained by the baseline differences in BP between study arms.Patient’s comfort and satisfaction are key drivers of compliance with CPAP treatment in the long term [
]. On the one hand, regarding comfort, the number of side effects in both arms was very similar. On the other hand, it must be noticed that in telemedicine interventions patients’ satisfaction is usually similar to or lower than that of usual care [ ], with privacy concerns being the main reported issue [ , ]. In this trial, all patients reported excellent satisfaction with their management, regardless of the study arm. Moreover, patients in the intervention group considered the MiSAOS app as useful and easy to use and reported their willingness to keep using it in the future. These results are better than those obtained in telemonitoring interventions in the same setting (Lleida, Spain) but not providing any direct feedback to the patients [ ] and confirm that patient empowerment has a direct impact on patient satisfaction. Finally, potential issues on data privacy had no impact on the current trial results, in contrast to previous research [ ], and in line with other interventions providing the patients with regular feedback on compliance [ ].A key aspect of any new management strategy is the cost of the intervention and its cost-effectiveness. In this study, the analysis of costs and cost-effectiveness showed that the MiSAOS intervention had an overall cost similar to that of usual care while providing better results in terms of treatment compliance, thus demonstrating cost-effectiveness. This result is in contrast to previous cost-effectiveness trials of telemonitoring interventions for CPAP-treated patients in Spain, where cost-effectiveness was demonstrated because of an overall reduction in costs and no significant differences in effectiveness were found [
, ]. Similarly, telemedicine platforms with automated functions to provide education or accountability have already shown cost-effectiveness in sleep medicine [ ]. This suggests that the addition of machine learning data–processing functionalities together with the empowerment of patients by means of direct feedback could tip the scales toward significant increases in compliance and boost the cost-effectiveness of already existing telemonitoring interventions. Moreover, it should be noticed that a key factor of telemonitoring is the reduction in the number or duration of follow-up visits, which was quantified by Anttalainen et al [ ], reporting a saving of 19 minutes in nursing time when comparing telemonitoring with usual care in the habituation phase of CPAP treatment (4 weeks) [ ], and should be sufficient to mitigate the costs of telemonitoring.Implications for Future Clinical Practice
As previously stated, the main barriers for the large-scale implementation of a novel management intervention are its costs and cost-effectiveness. In the optimal scenario, a novel management strategy should be cheaper than usual care while providing better results. The MiSAOS model has shown the potential to generate better results than usual care in terms of compliance. However, it was not cheaper than usual care. It is worth mentioning that a big proportion of the intervention’s cost corresponded to the use of a 2G (GSM/GPRS) system for daily CPAP compliance data transfer. This technology could be easily replaced by a secure wireless connection to the patients’ home Wi-Fi network, which would represent a huge saving and further boost cost-effectiveness. Even in rural areas such as Lleida, this scenario is rapidly becoming a reality and most homes have a suitable Wi-Fi network.
Conclusion
The use of a machine learning–based intelligent monitoring system increased daily compliance, reported an excellent patient satisfaction similar to that reported in usual care, and did not incur in a substantial increase in costs, thus proving cost-effectiveness. This study supports the implementation of intelligent eHealth frameworks for the management of patients with OSA treated by CPAP and confirms the value of patients’ empowerment in the management of chronic diseases.
Acknowledgments
This work is part of the myOSA project (RTC-2014-3138-1), funded by the Spanish Ministry of Economy, Industry and Competitiveness (Ministerio de Economía, Industria y Competitividad) and Agencia Estatal de Investigación, under the framework “Retos-Colaboración”, State Scientific and Technical Research and Innovation Plan 2013-2016. The work was cofunded by the European Regional Development Fund (ERDF), “A way to make Europe”. JdB acknowledges receiving financial support from the Catalan Health Department (Pla Estratègic de Recerca i Innovació en Salut [PERIS] 2016: SLT002/16/00364) and Instituto de Salud Carlos III (ISCIII; Miguel Servet 2019: CP19/00108), co-funded by the European Social Fund (ESF), “Investing in your future”. Funding organizations had no role in the design and conduct of the study; collection, management, analysis, and interpretation of the data; preparation, review, or approval of the manuscript; and decision to submit the manuscript for publication.
Authors' Contributions
CT, EV, JB, FB, and JdB participated in the conceptualization of project. CT, AL, LP, RV, and AC conducted data collection. CT, IB and AM-M participated in data curation. IB conducted all statistical analyses. CT, IB, and JdB wrote the original draft of the manuscript. All authors reviewed the final manuscript. JB and FB secured funding for the project.
Conflicts of Interest
None declared.
CONSORT-eHealth checklist (V 1.6.1).
PDF File (Adobe PDF File), 1751 KB
Screenshots of the MiSAOS app showing from left to right and top to bottom: (i) loading screen with the app’s name; (ii) last week’s overall CPAP treatment performance summary, including an overall numeric score (0-10) together with a summary smiley, average compliance in hours, average air leaks, average residual apnea-hypopnea index (AHI), specific compliances for the last 7 days, and a summary text including reinforcements and tips to improve the overall rating in upcoming weeks (in this case, a positive reinforcement message for and a tip regarding air-leaks and hours of use); (iii) last week’s overall CPAP treatment performance summary with focus on air-leaks, including last 14 days air-leak information and additional details; (iv) patient and device’s summary information including technical details on the CPAP treatment characteristics; (v) main achievements summary, including a ranking of the patient’s performance compared to other CPAP users in the region and challenges’ progression such as good compliance streaks; and, (vi) sample information and training screen, in this case explaining the basics of obstructive sleep apnea pathophysiology.
DOCX File , 825 KB
Screenshots of the MiSAOS website showing from top to bottom: (i) registry of events and actions taken in relation to a given patient, including date, action details and comments; (ii) example of data collection for the feed of the predictive algorithms; (iii) sample prediction provided by MiSAOS intelligent algorithms, in this case predicting 6-month compliance based on early compliance and information such as the one collected in the previous screenshot; and, (iv) example of available training material tackling the most common issues and doubts of patients (in addition to videos there are also manuals, FAQs, and tips).
DOCX File , 582 KB
Differences in primary and secondary outcomes of the trial according to a per-protocol analysis.
DOCX File , 18 KBReferences
- Senaratna CV, Perret JL, Lodge CJ, Lowe AJ, Campbell BE, Matheson MC, et al. Prevalence of obstructive sleep apnea in the general population: A systematic review. Sleep Medicine Reviews 2017 Aug;34:70-81. [CrossRef] [Medline]
- Sánchez-de-la-Torre M, Campos-Rodriguez F, Barbé F. Obstructive sleep apnoea and cardiovascular disease. The Lancet Respiratory Medicine 2013 Mar;1(1):61-72. [CrossRef]
- Iftikhar IH, Bittencourt L, Youngstedt SD, Ayas N, Cistulli P, Schwab R, et al. Comparative efficacy of CPAP, MADs, exercise-training, and dietary weight loss for sleep apnea: a network meta-analysis. Sleep Med 2017 Feb;30:7-14. [CrossRef] [Medline]
- Martínez-García MA, Capote F, Campos-Rodríguez F, Lloberes P, Díaz de Atauri MJ, Somoza M, Spanish Sleep Network. Effect of CPAP on blood pressure in patients with obstructive sleep apnea and resistant hypertension: the HIPARCO randomized clinical trial. JAMA 2013 Dec 11;310(22):2407-2415. [CrossRef] [Medline]
- Barbé F, Durán-Cantolla J, Sánchez-de-la-Torre M, Martínez-Alonso M, Carmona C, Barceló A, Spanish Sleep And Breathing Network. Effect of continuous positive airway pressure on the incidence of hypertension and cardiovascular events in nonsleepy patients with obstructive sleep apnea: a randomized controlled trial. JAMA 2012 May 23;307(20):2161-2168. [CrossRef] [Medline]
- Sawyer AM, Gooneratne NS, Marcus CL, Ofer D, Richards KC, Weaver TE. A systematic review of CPAP adherence across age groups: clinical and empiric insights for developing CPAP adherence interventions. Sleep Med Rev 2011 Dec;15(6):343-356 [FREE Full text] [CrossRef] [Medline]
- Hussain SF, Irfan M, Waheed Z, Alam N, Mansoor S, Islam M. Compliance with continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea among privately paying patients- a cross sectional study. BMC Pulm Med 2014 Nov 29;14(1):188 [FREE Full text] [CrossRef] [Medline]
- Campos-Rodriguez F, Martinez-Alonso M, Sanchez-de-la-Torre M, Barbe F. Long-term adherence to continuous positive airway pressure therapy in non-sleepy sleep apnea patients. Sleep Medicine 2016 Jan;17:1-6. [CrossRef]
- Rolfe I, Olson LG, Saunders NA. Long-term acceptance of continuous positive airway pressure in obstructive sleep apnea. Am Rev Respir Dis 1991 Nov;144(5):1130-1133. [CrossRef] [Medline]
- McArdle N, Devereux G, Heidarnejad H, Engleman HM, Mackay TW, Douglas NJ. Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 1999 Apr;159(4 Pt 1):1108-1114. [CrossRef] [Medline]
- Wozniak D, Lasserson T, Smith I. Educational, supportive and behavioural interventions to improve usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea. Cochrane Database Syst Rev 2014 Jan 08(1):CD007736. [CrossRef] [Medline]
- Bruyneel M. Telemedicine in the diagnosis and treatment of sleep apnoea. Eur Respir Rev 2019 Mar 31;28(151):180093 [FREE Full text] [CrossRef] [Medline]
- Pépin JL, Tamisier R, Hwang D, Mereddy S, Parthasarathy S. Does remote monitoring change OSA management and CPAP adherence? Respirology 2017 Nov 12;22(8):1508-1517. [CrossRef] [Medline]
- Aardoom JJ, Loheide-Niesmann L, Ossebaard HC, Riper H. Effectiveness of eHealth Interventions in Improving Treatment Adherence for Adults With Obstructive Sleep Apnea: Meta-Analytic Review. J Med Internet Res 2020 Feb 18;22(2):e16972 [FREE Full text] [CrossRef] [Medline]
- Rafael-Palou X, Vargiu E, Turino C, Steblin A, Sánchez-de-la-Torre M, Barbe F. Towards an Intelligent Monitoring System for Patients with Obstrusive Sleep Apnea. ICST Transactions on Ambient Systems 2017 Dec 19;4(16):153481. [CrossRef]
- Lloberes P, Durán-Cantolla J, Martínez-García, Marín JM, Ferrer A, Corral J, et al. Diagnosis and treatment of sleep apnea-hypopnea syndrome. Archivos de Bronconeumología ((English Edition)) 2011 Jan;47(3):143-156. [CrossRef]
- MiSAOS. URL: https://www.misaos.com [accessed 2021-09-19]
- Rafael-Palou X, Turino C, Steblin A, Sánchez-de-la-Torre M, Barbé F, Vargiu E. Comparative analysis of predictive methods for early assessment of compliance with continuous positive airway pressure therapy. BMC Med Inform Decis Mak 2018 Sep 18;18(1):81 [FREE Full text] [CrossRef] [Medline]
- CVE-DOGC-A-13051031-2013: Resolution SLT/353/2013, of February 13, on the review of public prices for the services provided by the Catalan Health Institute. URL: https://www.comb.cat/Upload/Documents/4635.pdf [accessed 2021-09-19]
- Pépin JL, Jullian-Desayes I, Sapène M, Treptow E, Joyeux-Faure M, Benmerad M, et al. Multimodal Remote Monitoring of High Cardiovascular Risk Patients With OSA Initiating CPAP: A Randomized Trial. Chest 2019 Apr;155(4):730-739. [CrossRef] [Medline]
- Stepnowsky C, Edwards C, Zamora T, Barker R, Agha Z. Patient perspective on use of an interactive website for sleep apnea. Int J Telemed Appl 2013;2013:239382-239310 [FREE Full text] [CrossRef] [Medline]
- Kuna ST, Shuttleworth D, Chi L, Schutte-Rodin S, Friedman E, Guo H, et al. Web-Based Access to Positive Airway Pressure Usage with or without an Initial Financial Incentive Improves Treatment Use in Patients with Obstructive Sleep Apnea. Sleep 2015 Aug 01;38(8):1229-1236 [FREE Full text] [CrossRef] [Medline]
- Hwang D, Chang JW, Benjafield AV, Crocker ME, Kelly C, Becker KA, et al. Effect of Telemedicine Education and Telemonitoring on Continuous Positive Airway Pressure Adherence. The Tele-OSA Randomized Trial. Am J Respir Crit Care Med 2018 Jan;197(1):117-126. [CrossRef]
- Frasnelli M, Baty F, Niedermann J, Brutsche MH, Schoch OD. Effect of telemetric monitoring in the first 30 days of continuous positive airway pressure adaptation for obstructive sleep apnoea syndrome – a controlled pilot study. J Telemed Telecare 2015 Aug 06;22(4):209-214. [CrossRef]
- Turino C, de Batlle J, Woehrle H, Mayoral A, Castro-Grattoni A, Gómez S, et al. Management of continuous positive airway pressure treatment compliance using telemonitoring in obstructive sleep apnoea. Eur Respir J 2017 Feb 08;49(2):1601128 [FREE Full text] [CrossRef] [Medline]
- Isetta V, Negrín MA, Monasterio C, Masa JF, Feu N, Álvarez A, Spanish Sleep Network. A Bayesian cost-effectiveness analysis of a telemedicine-based strategy for the management of sleep apnoea: a multicentre randomised controlled trial. Thorax 2015 Nov 26;70(11):1054-1061. [CrossRef] [Medline]
- Anttalainen U, Melkko S, Hakko S, Laitinen T, Saaresranta T. Telemonitoring of CPAP therapy may save nursing time. Sleep Breath 2016 Dec 4;20(4):1209-1215. [CrossRef] [Medline]
Abbreviations
AHI: Apnea–Hypopnea Index |
BP: blood pressure |
CPAP: continuous positive airway pressure |
ESS: Epworth Sleepiness Scale |
ITT: intention-to-treat |
OSA: obstructive sleep apnea |
PP: per protocol |
SEPAR: Spanish Respiratory Society |
Edited by R Kukafka; submitted 02.09.20; peer-reviewed by I Cano, R Halkes; comments to author 21.12.20; revised version received 02.03.21; accepted 12.08.21; published 18.10.21
Copyright©Cecilia Turino, Ivan D Benítez, Xavier Rafael-Palou, Ana Mayoral, Alejandro Lopera, Lydia Pascual, Rafaela Vaca, Anunciación Cortijo, Anna Moncusí-Moix, Mireia Dalmases, Eloisa Vargiu, Jordi Blanco, Ferran Barbé, Jordi de Batlle. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 18.10.2021.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included.