Review
Abstract
Background: Hyperglycemia in pregnancy occurs worldwide and is closely associated with health issues in women and their offspring, such as pregnancy and birth complications, respectively, as well as comorbidities, such as metabolic and cardiovascular diseases. To optimize the management of diabetic pregnancies, sustainable strategies are urgently needed. Investigation of constantly evolving technologies for diabetes that help to manage pregnancy and health is required.
Objective: We aimed to conduct a systematic review to assess the clinical effectiveness of technologies for diabetes in pregnancy.
Methods: Relevant databases including MEDLINE (PubMed), Cochrane Library, Embase, CINAHL, and Web of Science Core Collection were searched in September 2020 for clinical studies (2008-2020). Findings were organized by type of diabetes, type of technology, and outcomes (glycemic control, pregnancy- and birth-related outcomes, and neonatal outcomes). Study quality was assessed using Effective Public Health Practice Project criteria.
Results: We identified 15 randomized controlled trials, 3 randomized crossover trials, 2 cohort studies, and 2 controlled clinical trials. Overall, 9 studies focused on type 1 diabetes, 0 studies focused on gestational diabetes, and 3 studies focused on both type 1 diabetes and type 2 diabetes. We found that 9 studies were strong quality, 11 were moderate quality, and 2 were weak quality. Technologies for diabetes seemed to have particularly positive effects on glycemic control in all types of diabetes, shown by some strong and moderate quality studies. Positive trends in pregnancy-related, birth-related, and neonatal outcomes were observed.
Conclusions: Technologies have the potential to effectively improve the management of diabetes during pregnancy. Further research on the clinical effectiveness of these technologies is needed, especially in pregnant women with type 2 diabetes.
doi:10.2196/24982
Keywords
Introduction
Hyperglycemia in pregnancy occurs worldwide and is closely associated with short- and long-term health issues, such as pregnancy complications in women and birth complications in offspring, and comorbidities, such as type 2 diabetes, as well as metabolic and cardiovascular diseases [
]. Approximately 20.4 million live births (16%) suffered from some form of hyperglycemia in pregnancy in 2019, worldwide [ ]—84% were defined as gestational diabetes, 7.9% were diagnosed prior to pregnancy, and 8.5% were type 1 or type 2 diabetes first observed in pregnancy [ ].In 2019, 1,566,993.4 live births in North America and the Caribbean; 2,001,816.8 live births in Europe; and 6,594,159.4 live births in southeast Asia were affected by hyperglycemia in pregnancy [
]. Interestingly, the prevalence of gestational diabetes is rising quickly and was estimated to be 20.8% in North America and the Caribbean, 16.3% in Europe, and 27.0% in southeast Asia in 2019 [ ]. The number of unreported cases is assumed to be high.Hyperglycemia in pregnancy is associated with adverse pregnancy- and birth-related outcomes for mothers and offspring, such as increased risk of preeclampsia, cesarean deliveries, macrosomia, and shoulder dystocia [
- ], but hyperglycemia in pregnancy is also associated with adverse long-term consequences in mothers and children, such as subsequent increased risk of type 2 diabetes, obesity, metabolic syndrome, cardiovascular diseases, or even depression [ , , , , ]. Based on the hypotheses of perinatal programming (fetal programming, developmental programming, transgenerational programming), intrauterine exposure to hyperglycemia is clearly associated with obesity, glucose, intolerance, type 2 diabetes, insulin resistance, metabolic syndrome, high blood pressure, and cardiovascular diseases in postnatal life of the offspring [ , , ].Sustainable strategies are urgently needed to effectively improve the management of diabetes in pregnancy with seamlessly integrated technological support for hyperglycemia in pregnancy. Technologies for diabetes, including hardware, devices, and software, are constantly evolving and can help to manage the condition, improving lives and health [
]. Care 4.0 is a new paradigm to develop digital health and care services by focusing on trusted integrated networks of organizations, people, and technologies [ ].Recently, we demonstrated first insights in clinical effectiveness and successful approaches of mobile health (mHealth) apps as well as telemetric implementations to improve diabetic management in pregnancy [
, ]. Diabetes-specific mHealth apps and telemetric approaches improved clinical outcomes in the management of gestational diabetes effectively.As a matter of course, there are many more technologies that have proven to be effective in diabetes management in general, for example, continuous glucose monitoring systems [
, ], continuous subcutaneous insulin infusions [ , ], and sensor augmented insulin pumps or closed-loop systems [ , ].A previous review [
] examined the capability of diabetes technologies in the treatment of diabetic pregnancies; however, to further optimize management of diabetes in pregnancy, up-to-date analyses of technology for diabetes in pregnancies are needed. Therefore, we conducted a systematic review to assess the clinical effectiveness of different technologies for diabetes in pregnancies by analyzing glycemic control, pregnancy- and birth related outcomes, and neonatal outcomes.Methods
Data Sources and Searches
A systematic review was carried out using PRISMA guidelines [
]. MEDLINE (PubMed), Cochrane Library, Embase, CINAHL, and Web of Science Core Collection were systematically searched for studies published from January 2008 until September 2020 ( ). The following keywords were used as title and abstract search terms and selected from Medical Subject Headings and Embase subject headings databases: “diabetes mellitus,” “pregnancy,” “gestational diabetes mellitus,” “mobile application,” “insulin pump,” “continuous glucose monitoring,” “CGM,” “flash glucose monitoring,” “FGM,” “insulin infusion system” ( ). Using a priori criteria for eligibility, 2 reviewers screened and selected the studies independently. We screened titles and abstracts, assessed full texts, and manually searched reference lists and Google Scholar.Eligibility Criteria
We included peer-reviewed studies, published in German and English, that investigated the clinical effectiveness of diabetes technologies in pregnancies affected by hyperglycemia, including pre- and postconception. Studies with pregnant woman with a diagnosis of gestational diabetes or with preexisting type 1 diabetes or type 2 diabetes and that clearly reported the type of diabetes investigated were included. We included studies examining gestational diabetes patients only, type 1 diabetes only, type 2 diabetes only, and studies with mixed pregestational diabetes (type 1 diabetes and type 2 diabetes) groups. We included prospective controlled trials (clinical and observational trials). The following types of technologies were included: continuous glucose monitoring systems, continuous subcutaneous insulin infusions, sensor augmented insulin pumps, closed-loop systems, and mHealth apps. We involved studies examining glycemic control, pregnancy- and birth-related, and neonatal outcomes. Poster, comments, letter, study protocols, notes, and proceedings papers were excluded.
Data Extraction and Synthesis
We extracted the most common glycemic control (eg, hemoglobin A1c [HbA1c], fasting blood glucose, hyper- or hypoglycemia, insulin dose), pregnancy- and birth-related (eg, preterm birth, gestational weight gain), and neonatal (eg, birthweight, macrosomia) outcomes as well as author, year, study design, type of diabetes, type of technology, sample size, and main results. Findings were organized by type of diabetes, type of technology, and outcomes.
Quality Assessment
We applied Effective Public Health Practice Project (EPHPP), a validated tool that is suitable for intervention studies such as randomized controlled trials and controlled clinical trials. EPHPP is composed of criteria regarding selection bias, study design, confounders, blinding, data collection methods, withdrawals, and dropout. Study quality is rated as strong (SQ), moderate (MQ), or weak (WQ) [
].Results
Study Selection and Characteristics
The search yielded 974 records, of which 754 remained after removing duplicates (3 records were identified through reference lists and Google Scholar). Of those, 693 were excluded based on titles and abstracts with our inclusion and exclusion criteria, and the full texts of 61 remaining publications were screened. Finally, 22 studies were included in this systematic review: 15 randomized controlled trials, 3 randomized crossover trials, 2 cohort studies, and 2 controlled clinical trials. Overall, 9 studies focused on type 1 diabetes, 10 studies focused on gestational diabetes, and 3 studies focused on type 1 diabetes and type 2 diabetes (mixed populations). We rated 9 studies as strong quality, 11 studies as moderate quality, and 2 studies as weak quality (
). gives an overview of the technologies, outcomes, and number of study participants..Population, technology, and outcome | Studies, n | Intervention group, n | Control group, n | ||
Type 1 diabetes | |||||
Continuous glucose monitoring systems | |||||
HbA1ca | 3 | 199 | 236 | ||
Maternal hypoglycemia | 2 | 172 | 177 | ||
Insulin dose and insulin requirements | 3 | 199 | 236 | ||
Cesarean and vaginal deliveries | 3 | 139 | 174 | ||
Preterm birthb | 3 | 139 | 174 | ||
Maternal weight gain | 2 | 112 | 115 | ||
Neonatal birthweight | 2 | 127 | 159 | ||
Neonatal macrosomia | 2 | 112 | 113 | ||
Large for gestational age | 2 | 127 | 113 | ||
Continuous subcutaneous insulin infusion | |||||
HbA1c | 4 | 218 | 485 | ||
Insulin dose | 2 | 145 | 292 | ||
Maternal hypoglycemia | 2 | 160 | 237 | ||
Maternal weight gain | 2 | 223 | 273 | ||
Cesarean delivery | 3 | 271 | 353 | ||
Preterm birth | 3 | 271 | 353 | ||
Maternal hypertension and preeclampsia | 2 | 159 | 196 | ||
Neonatal birthweight | 2 | 158 | 195 | ||
Macrosomia (≥4000 g) | 2 | 158 | 195 | ||
Large for gestational age | 2 | 158 | 195 | ||
Small for gestational age | 2 | 158 | 195 | ||
Admission to a higher level of neonatal care | 2 | 158 | 195 | ||
Neonatal hypoglycemia | 2 | 158 | 195 | ||
Closed-loop systems | |||||
Hypoglycemic events, insulin dose | 2 | 16 | 16 | ||
Gestational diabetes | |||||
Continuous glucose monitoring systems | |||||
HbA1c | 3 | 96 | 99 | ||
Fasting blood glucose | 2 | 85 | 87 | ||
Preterm birth | 3 | 96 | 99 | ||
Cesarean and vaginal deliveries | 3 | 87 | 92 | ||
Maternal weight gain | 2 | 76 | 80 | ||
Neonatal birthweight | 4 | 147 | 154 | ||
Macrosomia (≥4000 g) | 4 | 147 | 154 | ||
Large for gestational age | 3 | 87 | 92 | ||
Small for gestational age | 3 | 87 | 92 | ||
Admission to a higher level of neonatal care | 3 | 96 | 99 | ||
Neonatal hypoglycemia | 3 | 136 | 142 | ||
mHealth apps | |||||
HbA1c | 2 | 164 | 161 | ||
Fasting blood glucose | 2 | 69 | 62 | ||
Off-target fasting blood glucose measurement | 2 | 124 | 120 | ||
Patient compliancec | 2 | 124 | 120 | ||
Pregnancy-induced hypertension or preeclampsia | 3 | 218 | 212 | ||
Preterm birth | 2 | 158 | 152 | ||
Vaginal and cesarean deliveries | 5 | 390 | 393 | ||
Neonatal birthweight | 3 | 218 | 211 | ||
Macrosomia | 3 | 233 | 231 | ||
Neonatal hypoglycemia | 4 | 277 | 263 | ||
Admission to a higher level of neonatal care | 4 | 330 | 330 | ||
Type 1 and type 2 diabetes | |||||
Continuous glucose monitoring systems | |||||
HbA1c | 2 | 117 | 108 | ||
Plasma glucose | 1 | 79 | 75 | ||
Preeclampsia | 2 | 117 | 108 | ||
Cesarean delivery | 2 | 117 | 108 | ||
Preterm birth | 2 | 117 | 108 | ||
Neonatal birthweight | 2 | 117 | 108 | ||
Large for gestational age | 2 | 117 | 108 | ||
Neonatal hypoglycemia | 2 | 117 | 108 | ||
Continuous subcutaneous insulin infusion | |||||
HbA1c | 1 | 24 | 18 |
aHbA1c: hemoglobin A1c.
bPreterm delivery was defined as <37 weeks.
cPatient compliance was defined as ratio between actual and instructed blood glucose measurements×100.
Type 1 Diabetes: Overview
Of 9 publications analyzing 379 women in intervention (IG) and 763 in control groups (CG), 3 studies examined continuous glucose monitoring system, 4 studies examined continuous subcutaneous insulin infusion, and 2 studies examined closed-loop systems.
Type 1 Diabetes: Continuous Glucose Monitoring Systems
In general, 3 randomized controlled trials [
- ], analyzing 199 women in intervention groups and 236 women in control groups, were identified.Glycemic Control Outcomes
HbA1c values declined in all interventions. Feig et al [
] (MQ) observed significantly lower HbA1c values in the intervention group than the control group (mean difference −0.19%; 95% CI −0.34 to −0.03; P=.0207). Cordua et al [ ] (SQ) found positive but nonsignificant effects (IG: 6.0% vs CG: 6.2%; P=.23), and Petrovski et al [ ] (SQ) reported significantly improved HbA1c values (P<.05) in both groups (real-time continuous glucose monitoring system and intermittent continuous glucose monitoring system).Petrovski et al [
] (SQ) found significantly less severe events of maternal hypoglycemia (real-time continuous glucose monitoring system group: P<.05), whereas Feig et al [ ] (MQ) found time spent hypoglycemic was comparable in both groups (3% vs 4%; P=.10).The intervention groups tended to have better target insulin dose or requirement values than those of the control groups (P=.14 [
], MQ; P=.08 [ ], SQ). Petrovski et al [ ] (SQ) did not find significant differences between constant and intermittent continuous glucose monitoring system (P>.05).Pregnancy- and Birth-Related Outcomes
Cesarean delivery rates were clearly lower in the intervention groups (MQ, P=.18 [
]; SQ, P<.05 [ ]). Cordua et al [ ] (SQ) found significantly more vaginal deliveries in the intervention groups (IG: 74%; CG: 54%; P=.08).All studies found slightly fewer preterm births in the interventions groups (Feig et al [
] <37 weeks: P=.57; <34 weeks: P=.19; Petrovski et al [ ]: P>.05, Cordua et al [ ]: P=.84).Maternal gestational weight gains were lower in the continuous glucose monitoring system group (Feig et al [
] +8.9 kg vs +9.7 kg, P=.09) and the intermittent continuous glucose monitoring system group (Petrovski et al [ ] +12.9 kg vs 13.4 kg, P>.05).Neonatal Outcomes
Feig et al [
] (MQ) displayed a slightly lower mean birthweight in the continuous glucose monitoring system group (P=.37), whereas Cordua et al [ ] (SQ) found a lower mean birthweight in their control group (P=.19).Macrosomia rates were lower in intervention (Feig et al [
], MQ, IG: 23%; CG: 27%; P=.62) and real-time continuous glucose monitoring system (Petrovski et al [ ], SQ, P>.05) groups.Feig et al [
] found rates for large for gestational age were significantly lower in the intervention groups (P=.021), whereas Cordua et al [ ] found no significant differences (P=.08).Type 1 Diabetes: Continuous Subcutaneous Insulin Infusion
In general, 2 cohort studies [
, ], 1 randomized controlled trials [ ], 1 randomized crossover trial [ ] analyzing 148 intervention and 495 control participants were identified.Glycemic Control Outcomes
Overall, 3 studies found positive effects on HbA1c levels in favor of continuous subcutaneous insulin infusion. Jotic et al [
] (SQ) found a significant lower mean HbA1c level in their intervention group than that in the control group at follow-up (6.5% intervention vs 6.8% control, P=.002). Cyganek et al [ ] (SQ) also reported significant improvements in HbA1c within all their treatment groups but did not find significant differences between groups.Gutaj et al [
] (SQ) found significant lower insulin doses in the intervention group (0.54 U/kg/day intervention vs 0.63 U/kg/day control, P=.02), whereas Cyganek et al [ ] (SQ) showed significantly lower daily insulin doses within each treatment group but no significant differences between groups.Jotic et al [
] (SQ) reported that in early pregnancy, the majority of women on continuous subcutaneous insulin infusion had significantly fewer instances of hypoglycemia (P<.01), but Cyganek et al [ ] (SQ) found fewer instances of severe hypoglycemia in their control group (P=.04).Pregnancy- and Birth-Related Outcomes
Cyganek et al [
] (SQ) found less weight gain (+13.0 kg) in women in the control group receiving multiple daily injections than in the other groups (+14.7 kg for those only continuous subcutaneous insulin infusion; +15.2 kg for those moving from multiple daily injections to continuous subcutaneous insulin infusion; P=.005), and Feig at al [ ] (MQ) did not find significant differences between groups (IG: mean +13.5 kg, SD 5.4 kg; CG: mean+13.5 kg, SD 0.7 kg; P=.48).The studies could not find any clearly positive effects regarding cesarean deliveries in favor of continuous subcutaneous insulin infusion. Cyganek et al [
] (SQ) reported that the proportion of cesarean deliveries was larger in women using insulin pumps (no P value reported) because of clinical factors such as age, duration of diabetes, and microvascular complications. Feig et al [ ] (MQ) (IG: n=81 vs CG: n=74, P=.32) and Jotic et al [ ] (SQ) (IG: n=12 vs CG: n=13, P=.20) found no significant differences between groups.There were no significant differences in preterm births between groups (P=.30 [
]; pump: n=39, 35%, vs multiple daily injections: n=35, 30%, P=.10 [ ]; continuous subcutaneous insulin infusion n=13, 27.7%, vs multiple daily injections n=13, 16.3%, P=.17 [ ]).Feig et al [
] (MQ) found significantly fewer women with hypertension in the control group (IG: 14.4% vs CG: 5.2%; P=.025), whereas Jotic et al [ ] (SQ) reported a lower, but not significantly so, rate of women with hypertension in their intervention group (P=.09). Feig et al [ ] (MQ) also found fewer women with preeclampsia in the control group (P=.31), whereas Jotic et al [ ] (MQ) noted fewer women with preeclampsia in the intervention group (IG: n=1, CG: n=3, P value not available).Neonatal Outcomes
Neonatal birthweight was marginally higher in intervention groups (Feig et al [
], MQ, P=.91; Jotic et al [ ], SQ, P=.98).Jotic et al [
] (SQ) found fewer instances of macrosomia in the intervention group (P=.46), while Feig et al [ ] (MQ) found slightly more instances in the intervention group (P=.89).Jotic et al [
] reported fewer instances of newborns being large for gestational age in the intervention group (P=.59 [ ]), whereas Feig et al found slightly more newborns who were large for gestational age in the interventions group (P=.55).Jotic et al [
] (SQ) found no instances of newborns being small for gestational age in the intervention and 5 (4%) instances of newborns being small for gestational age in the control group (P value not available), whereas Feig et al [ ] (MQ) observed 3 and 1 instances of newborns being small for gestational age in the intervention and control groups, respectively (P value not available).Feig et al [
] (MQ) and Jotic et al [ ] (SQ) found differences in admissions to higher level neonatal care in favor of the control groups (IG: 44.5% vs CG: 29.6%, P=.02 [ ]; and P=.28 [ ]).Jotic et al [
] (SQ) found slightly fewer instances of neonatal hypoglycemia in the intervention group (IG: n=5, CG: n=6, P=.54), whereas Feig et al [ ] (MQ) reported a significant difference in favor of the control group (IG: 31.8% vs CG: 19.1%, P=.05).Type 1 Diabetes: Closed-Loop Systems
Closed-loop systems were investigated in 2 randomized crossover trials including a total of 32 women comparing closed-loop systems with sensor augmented insulin pumps [
, ].Stewart et al [
] found a significant difference between groups in percentage of time that blood glucose levels were between 63 and 140 mg/dL for overnight evaluation (P=.002) as well as day and night evaluation (P<.001) in favor of the closed-loop group [ ], while Stewart et al [ ] (MQ) found no significant difference (closed-loop: 62.3% vs sensor augmented insulin pumps: 60.1%, 95% CI 24.1% to 8.3%, P=.47).Stewart et al [
] (MQ) reported significant fewer hypoglycemic events during the closed-loop treatment (n=8 vs n=12.5, P=.04) [ ], whereas Stewart et al [ ] (MQ) found no significant differences in overnight analysis (closed-loop: median 3.0; sensor augmented insulin pumps: median 2.5, P=.68) or day and night analysis (closed-loop: median 11.0, sensor augmented insulin pumps: median 12.0, P=.19).Neither Stewart et al [
] (MQ) (closed-loop 43.7 vs sensor augmented insulin pumps 41.5 units/day, P=.56) nor Stewart et al [ ] (MQ) (closed-loop 58.2 vs sensor augmented insulin pumps 59.8 units/day, P=.56) found significant differences between treatments regarding insulin dose [ , ].Gestational Diabetes: Overview
In general, 4 studies focused on continuous glucose monitoring system, and 6 studies focused on mHealth apps (overall: IG: n=555; CG: n=609).
Gestational Diabetes: Continuous Glucose Monitoring Systems
We identified 4 randomized controlled trials (IG: n=147, CG: n=154). Whereas 3 studies used self-monitoring blood glucose as control [
- ], 1 study used blinded continuous glucose monitoring system which did not display the glucose readings to the participant [ ].Glycemic Control Outcomes
All studies reported clearly lower HbA1c values in their intervention groups. Paramasivam et al [
] (MQ) found a significant difference in favor of the intervention group (mean 5.2%, SD 0.4% vs mean 5.6%, SD 0.6%; P=.006). Alfadhli et al [ ] (P=.168) (MQ) and Lane et al [ ] (P=.3) (SQ) found lower mean HbA1c values in their intervention groups (P>.05).Paramasivam et al [
] (MQ) (P=.101) and Alfadhli et al [ ] (P=.092) (MQ) found lower fasting blood glucose values in the intervention groups.Pregnancy- and Birth-Related Outcomes
Alfadhli et al [
] (MQ) (IG=16.3%, CG=9.5%, P=.373), Paramasivam et al [ ] (MQ) (IG: n=3, 12%; CG: n=1, 4%; P=.609) and Lane et al [ ] (SQ) (IG: n=1, 9.1%; CG: n=2, 16.7%; P>.999) found no significant differences in the occurrence of preterm births.Paramasivam et al [
] (MQ) reported clearly more vaginal deliveries in the intervention group (P=.258) [ ], while Wei et al [ ] (MQ) (P=.370) and Lane et al [ ] (SQ) (P>.999) noted slightly more cesarean deliveries in the control groups.Both studies showed positive effects on maternal weight gain. Wei et al [
] (MQ) reported that the intervention participants had significantly more appropriate and less excessive weight gain (P=.039) and Paramasivam et al [ ] (MQ) mentioned slightly less weight gain in the intervention group (P=.917).Neonatal Outcomes
Wei et al [
] (P=.084), Alfadhli et al [ ] (MQ) (P=.130) and Paramasivam et al [ ] (MQ) (P=.311) reported a lower, yet not significant, mean birthweight of newborns in the intervention groups. Lane et al [ ] (SQ) reported a higher mean birthweight of newborns in the intervention group (P=.4).Wei at al [
] (MQ) (P=.410) and Alfadhli et al [ ] (MQ) (P=.488) reported fewer instances of macrosomia in the intervention groups, while Lane et al [ ] (SQ) noted more instances of macrosomia in the intervention group (P=.2), and Paramasivam et al (MQ) [ ] found none.Wei et al [
] (MQ) (P=.071) and Paramasivam et al [ ] (MQ) (P=.490) found clearly fewer instances of newborns being large for gestational age in their intervention groups and, in contrast, Lane et al [ ] (SQ) found more instances of newborns being large for gestational age in the intervention group (P=.2).Lane et al [
] (SQ) (P>.999) and Wei et al [ ] (MQ) (P>.999) reported very slightly fewer instances of newborns being small for gestational age in the intervention groups. Paramasivam et al [ ] reported none.Alfadhli et al [
] (MQ) (P=.653) reported slightly more admissions, Lane et al [ ] (P>.999) noted slightly fewer, and Paramasivam et al [ ] (MQ) (both groups n=1, 4%) observed the same number of admissions (P>.999) to a higher level of neonatal care.Wei at al [
] (MQ) (P=.410) and Paramasivam et al [ ] (MQ) (P>.999) reported slightly fewer instances of neonatal hypoglycemia among intervention participants whereas Alfadhli et al [ ] (MQ) (P=.758) found slightly fewer instances of neonatal hypoglycemia in the control group.Gestational Diabetes: mHealth Apps
We identified 5 randomized controlled trials and 1 controlled clinical trial investigating a total of 408 women in the intervention and 405 women in the control groups.
Glycemic Control Outcomes
Overall, the intervention groups showed lower HbA1c values than the control groups. Guo et al [
] (SQ) displayed a significant difference in favor of the intervention group (–1.3% intervention vs –0.6% control, P<.001), while Mackillop et al [ ] (WQ) recognized a slight increase in both groups (IG: 0.02% per 28 days; CG: 0.03% per 28 days; 95% CI –0.05 to 0.03).Both Yang et al [
] (MQ) (P<.001) and Bromuri et al [ ] (MQ) (P<.001) found clear, significant differences in fasting blood glucose levels favoring the intervention groups.Miremberg et al [
] (SQ) (P<.001) as well as Guo et al [ ] (SQ) (P<.001) found significant differences in off-target fasting blood glucose measurement favoring the intervention groups [ , ].Guo et al [
] (SQ) (P<.001) and Miremberg et al [ ] (SQ) (P<.001) reported significant differences in support of the intervention groups in patient compliance (defined as ratio between actual and instructed blood glucose measurements×100).Pregnancy- and Birth-Related Outcomes
All intervention groups showed lower rates of pregnancy-induced hypertension or preeclampsia, but no significant differences were found by Mackillop et al [
] (WQ) (P=.22), Miremberg et al [ ] (SQ) (P>.99), or Yang et al [ ] MQ) (P=.347).Overall, there were fewer preterm births in the intervention groups, but neither Yang et al [
] (MQ) (P=.248) nor Mackillop et al [ ] (WQ) (P>.05) found significant differences.Positive intervention effects—more vaginal deliveries and less cesarean sections—were observed in almost all studies [
- , , ]; 2 studies showed statistical significance (Borgen et al [ ], WQ, P=.03; Mackillop et al [ ], WQ, P=.005).Neonatal Outcomes
The results show a clear trend toward lower birthweight in the newborns of the intervention groups, but no significant differences were found by Mackillop et al [
] (WQ) (P=.18), Miremberg et al [ ] (SQ) (P=.878), or Yang et al [ ] (MQ) (P=.988).Fewer instances of macrosomia occurred in the intervention groups than in the control groups, but no significant differences were found by Guo et al [
] (SQ) (P=.295), Yang et al (MQ) [ ] (P=.542) and Borgen et al [ ] (WQ) (P=.69).In general, most studies showed positive intervention effects. Guo et al [
] (SQ)(P=.185), Mackillop et al (WQ) [ ] (P=.42) and Yang et al (MQ)[ ] (P value not available) observed slightly fewer instances of neonatal hypoglycemia for intervention participants.The results show a trend toward infants of mothers in the interventions groups being transferred less often to neonatal intensive care units (Borgen et al [
], WQ, P=.38; Mackillop et al [ ], WQ, P=.08; Miremberg et al [ ], SQ, P>.99; Yang et al [ ], MQ, P=.657).Type 1 and Type 2 Diabetes: Overview
In total, 3 studies analyzing 141 women in the intervention and 126 women in the control groups were included [
- ]. Two studies observed continuous glucose monitoring system and one insulin pumps.Type 1 and Type 2 Diabetes: Continuous Glucose Monitoring Systems
Overall, 2 randomized controlled trials analyzed 117 intervention and 108 control participants. Secher et al [
] included 123 women with type 1 diabetes and 31 women with type 2 diabetes, while Murphy et al [ ] included 45 women with type 1 diabetes and 25 type 2 diabetes.Glycemic Control Outcomes
Murphy et al [
] (MQ) noted that HbA1c levels were consistently and significantly lower in the intervention group (gestation 32-36 weeks: P=.007), while Secher et al [ ] (MQ) reported comparable HbA1c values (IG: 6.1%, 95% CI 5.1%-7.8%; CG: 6.1%, 95% CI 4.8%-8.2%; P=.39).Median self-monitored plasma glucose levels at 33 weeks were comparable between groups (IG: 6.2 mmol/L, 4.7-7.9; CG: 6.2 mmol/L, 4.9-7.9) [
].Pregnancy- and Birth-Related Outcomes
Secher et al (MQ) and Murphy et al (MQ) observed very slightly more instances of preeclampsia in the treatment groups (P=.83 [
] and P=.5 [ ], respectively).Secher et al [
] (MQ) observed a lower rate of cesarean delivery (P=.30) and Murphy et al [ ] (MQ) reported a lower emergency cesarean delivery rate (P=.3) in the intervention group.Murphy et al [
] (MQ) observed slightly fewer preterm births (P=.8), whereas Secher et al [ ] (MQ) reported slightly more preterm births (P=.47) in the treatment group.Neonatal Outcomes
Murphy et al [
] (MQ) found significantly lower median birthweight percentile in the intervention group (69 vs 93, P=.02), whereas Secher et al [ ] (MQ) found the birthweight was slightly higher in the intervention group (3510 g vs 3436 g, P=.80).Murphy et al [
] (MQ) reported that fewer newborns who were extremely large for gestational age (≥97.7th percentile) were born to intervention participants (14% vs 30%, P=.1 ]), whereas Secher et al [ ] (MQ) reported slightly more newborns who were extremely large for gestational were born to participants in the treatment group (P=.19 [ ]).Both studies reported clearly fewer instances of neonatal hypoglycemia in the intervention groups (36% vs 40%, P=.62 [
]; and 8% vs 17%, P=.5 [ ])Type 1 and Type 2 Diabetes: Continuous Subcutaneous Insulin Infusion
One study [
] examined continuous subcutaneous insulin infusion compared to conventional insulin therapy (intervention n=24 vs control n=18). Kernaghan et al [ ] (SQ) included n=1 women with type 2 diabetes.The intervention group showed lower mean HbA1c levels in the first (P=.41) and second (P=.27) trimester. The birthweight z score was slightly lower in the control group (P=.86). The mean estimated fetal weight z score was lower in the intervention group (P=.16).
Discussion
Principal Results
In general, technologies seemed to have particularly positive effects on glycemic control in all types of diabetes, as shown by studies of strong and moderate quality. For type 1 diabetes, there were no studies evaluating the effectiveness of mHealth apps and, for gestational diabetes, there were no studies that evaluated the effectiveness of continuous subcutaneous insulin infusion or closed-loop systems. It is particularly useful for women with pregestational diabetes to use mHealth apps, as they can become familiar with them before pregnancy. Furthermore, there is a lack of research focusing on the effectiveness of technologies for pregnant women with type 2 diabetes.
Type 1 Diabetes
Continuous Glucose Monitoring Systems
Overall, glycemic control improved with continuous glucose monitoring systems in strong and moderate quality studies, especially HbA1c. Positive trends were observed for hypoglycemia and insulin dose. Intermittent continuous glucose monitoring systems seemed to be preferable to real-time continuous glucose monitoring systems, with fewer cesarean deliveries and more vaginal deliveries; however, the findings were not statistically significant. Regarding maternal weight gain and preterm births, improvements seem to be possible through the use of continuous glucose monitoring system, especially intermittent continuous glucose monitoring systems. Birthweight, large for gestational age, macrosomia, and neonatal hypoglycemia rates showed trends for improvement with continuous glucose monitoring system, as some moderate and strong quality studies showed nonsignificant, positive effects.
Continuous Subcutaneous Insulin Infusion
Overall, continuous subcutaneous insulin infusion improved glycemic control, especially HbA1c and insulin dose, as most strong and moderate quality studies showed positive intervention effects. In the case of maternal hypoglycemia, one study [
] found significantly fewer instances in the intervention group, but another study [ ] found fewer instances in the control group.No clear trend regarding the effectiveness of continuous subcutaneous insulin infusion can be derived regarding pregnancy- and birth-related outcomes such as maternal weight gain, preterm births, cesarean delivery, maternal hypertension, or preeclampsia. There were no clear trends in relation to neonatal outcomes such as birthweight, large for gestational age, small for gestational age, macrosomia, hypoglycemia, and admission to high-level neonatal care because too little data were available.
Closed-Loop Systems
A trend toward improved glycemic control was shown in moderate quality studies, but the sample size was very small (n=32 patients).
Gestational Diabetes
Continuous Glucose Monitoring Systems
In general, continuous glucose monitoring system improved glycemic control, particularly HbA1c and fasting blood glucose levels in strong and moderate quality studies; however, there was no obvious trend regarding 2-hour plasma blood glucose level and insulin dose. There were also no clear trends regarding preterm births or cesarean and vaginal deliveries. Both studies examining maternal weight gain showed positive but nonsignificant intervention effects.
Moreover, continuous glucose monitoring system improved birthweight, macrosomia, large for gestational age, small for gestational age, and neonatal hypoglycemia measures compared to those in control groups, though not significantly. Overall, there was no clear trend with respect to admission to higher level of neonatal care.
mHealth Apps
Gestational diabetes–specific mHealth apps displayed positive, significant effects in glycemic control outcomes such as HbA1c level, fasting blood glucose level, off-target blood glucose measurement, and patient adherence (actual vs instructed blood glucose measurements) in strong and moderate quality studies. mHealth apps improved pregnancy-induced hypertension or preeclampsia and preterm birth outcomes, but not significantly. In addition, the treatments showed positive effects regarding vaginal deliveries and cesarean deliveries. Gestational diabetes–specific mHealth apps indicated noticeable positive, but not significant effects, on neonatal outcomes such as birthweight, macrosomia, hypoglycemia, and rate of admission to a higher level of care.
Type 1 and Type 2 Diabetes
Continuous Glucose Monitoring Systems
The sample sizes of the studies were very small. One moderate-quality study [
] could not find any clear differences in HbA1c values between intervention and control group, while another moderate-quality study [ ] showed significant positive intervention effects. Cesarean deliveries were required less often. There was no obvious trend regarding preeclampsia and preterm births. While no clear effects were found regarding birthweight and being large for gestational age, continuous glucose monitoring system showed an improvement in terms of neonatal hypoglycemia outcomes, but not significantly.Continuous Subcutaneous Insulin Infusion
One strong-quality study [
] indicated positive trends in terms of HbA1c, birthweight z score, and estimated fetal weight z score.Strengths and Limitations
To our knowledge, this is the first systematic review of different technologies for diabetes that differentiated between various types of diabetes. Hence, our review opens up new perspectives on the topic hyperglycemia in pregnancy. However, the body of research included in this review may be limited depending on the type of diabetes and technology. Further research, with larger sample sizes and that takes into account women in the pre-conception phase, is needed, especially. Furthermore, we included only German and English papers, and we performed a qualitative analysis.
Comparison With Prior Work
Our results are in line with those from other reviews. In their systematic review, Feig et al [
] also reported that continuous glucose monitoring system improved HbA1c values in patients with type 1 diabetes. Furthermore, they showed lower rates of large for gestational age, higher time in range, and fewer adverse neonatal outcomes [ ].In their meta-analysis, Rys et al [
] investigated HbA1c values in pregnant women with type 1 diabetes using continuous subcutaneous insulin infusion or multiple daily injections. They reported lower HbA1c in the first trimester for continuous subcutaneous insulin infusion users (weighted mean difference: −0.45%; 95% CI −0.62 to −0.27).Research on gestational diabetes–specific mHealth apps is very limited. Skar et al [
] reported gestational diabetes–specific mHealth apps to be effective in increasing the confidence of women with gestational diabetes in their self-management and their motivation for behavior changes. In addition, Chen et al [ ] concluded that gestational diabetes specific mHealth apps can provide time- and cost-efficient personalized interventions to improve gestational diabetes management and clinical outcomes. Yu et al [ ] reported a clear superiority of continuous glucose monitoring system compared to self-monitoring blood glucose in detecting hypo- and hyperglycemic episodes.Conclusions
Technologies for diabetes seem to have a particularly positive effect on glycemic control in all types of diabetes. In pregnant women with type 1 diabetes, continuous glucose monitoring system as well as closed-loop systems seem to improve glycemic control. In women with gestational diabetes, the use of continuous glucose monitoring system systems has been shown, by this review, to improve glycemic control. mHealth apps can also improve glycemic control as well as certain pregnancy and birth related and neonatal outcomes in women with gestational diabetes.
Furthermore, this review showed that there is a lack of research on the clinical effectiveness of technologies for pregnant women with type 2 diabetes. In addition, sample sizes were, in many cases, rather small. Further research is needed to gain more firm evidence on the clinical effectiveness of diabetes technologies in pregnant women.
Acknowledgments
This manuscript was created in the context of a project funded by the German Research Foundation (Deutsche Forschungsgemeinschaft, EB 440/4-1); therefore, we would like to thank the Deutsche Forschungsgemeinschaft.
Conflicts of Interest
None declared.
Search strategies.
DOCX File , 20 KB
PRISMA flow diagram.
DOCX File , 43 KB
Quality assessment using Effective Public Health Practice Project criteria.
DOCX File , 27 KBReferences
- Diabetes atlas 9th edition. International Diabetes Federation. 2019. URL: https://www.diabetesatlas.org/en/ [accessed 2021-04-19]
- Chiefari E, Arcidiacono B, Foti D, Brunetti A. Gestational diabetes mellitus: an updated overview. J Endocrinol Invest 2017 Sep;40(9):899-909. [CrossRef] [Medline]
- Ferrara A. Increasing prevalence of gestational diabetes mellitus: a public health perspective. Diabetes Care 2007 Jul;30 Suppl 2:S141-S146. [CrossRef] [Medline]
- Eberle C. Fetale Programmierung des Diabetes mellitus Typ 2. MMW - Fortschritte der Medizin 2016 Aug 13;152(S3):76-82. [CrossRef]
- Eberle C, Ament C. Diabetic and metabolic programming: mechanisms altering the intrauterine milieu. ISRN Pediatr 2012;2012:975685 [FREE Full text] [CrossRef] [Medline]
- Eberle C, Ament C. A combined in vivo and in silico model shows specific predictors of individual trans-generational diabetic programming. J Dev Orig Health Dis 2020 Aug 18:1-8. [CrossRef] [Medline]
- Bellamy L, Casas J, Hingorani AD, Williams D. Type 2 diabetes mellitus after gestational diabetes: a systematic review and meta-analysis. Lancet 2009 May 23;373(9677):1773-1779. [CrossRef] [Medline]
- Kozhimannil KB, Pereira MA, Harlow BL. Association between diabetes and perinatal depression among low-income mothers. JAMA 2009 Feb 25;301(8):842-847. [CrossRef] [Medline]
- West NA, Crume TL, Maligie MA, Dabelea D. Cardiovascular risk factors in children exposed to maternal diabetes in utero. Diabetologia 2011 Mar;54(3):504-507 [FREE Full text] [CrossRef] [Medline]
- Tam WH, Ma RCW, Yang X, Li AM, Ko GTC, Kong APS, et al. Glucose intolerance and cardiometabolic risk in adolescents exposed to maternal gestational diabetes: a 15-year follow-up study. Diabetes Care 2010 Jun;33(6):1382-1384 [FREE Full text] [CrossRef] [Medline]
- American Diabetes Association. Diabetes technology. Diabetes Care 2020 Jan;43(Suppl 1):S77-S88. [CrossRef] [Medline]
- Chute C, French T. Introducing Care 4.0: an integrated care paradigm built on industry 4.0 capabilities. Int J Environ Res Public Health 2019 Jun 25;16(12):1-17 [FREE Full text] [CrossRef] [Medline]
- Eberle C, Ament C. Diabetologie und Stoffwechsel 2017 May 5;12(S 01):S1-S84. [CrossRef]
- Eberle C. Einsatz neuer Technologien in Diagnostik und Therapie: Diabetes-Smartphone-Apps. In: Stupin J, Schäfer-Graf U, Hummel M, editors. Diabetes in der Schwangerschaft 1. Auflage. Berlin: De Gruyter; 2020.
- Acosta GJ, Brown S, Zand AM, Kansara A, Sadhu A. USA vs Europe: who is leading the diabetes tech race? Curr Diab Rep 2019 Nov 16;19(11):128. [CrossRef] [Medline]
- Aleppo G, Ruedy KJ, Riddlesworth TD, Kruger DF, Peters AL, Hirsch I, REPLACE-BG Study Group. REPLACE-BG: a randomized trial comparing continuous glucose monitoring with and without routine blood glucose monitoring in adults with well-controlled type 1 diabetes. Diabetes Care 2017 Apr;40(4):538-545 [FREE Full text] [CrossRef] [Medline]
- McAdams BH, Rizvi AA. An overview of insulin pumps and glucose sensors for the generalist. J Clin Med 2016 Jan 04;5(1):5 [FREE Full text] [CrossRef] [Medline]
- Sora ND, Shashpal F, Bond EA, Jenkins AJ. Insulin pumps: review of technological advancement in diabetes management. Am J Med Sci 2019 Nov;358(5):326-331. [CrossRef] [Medline]
- Ly TT, Nicholas JA, Retterath A, Lim EM, Davis EA, Jones TW. Effect of sensor-augmented insulin pump therapy and automated insulin suspension vs standard insulin pump therapy on hypoglycemia in patients with type 1 diabetes: a randomized clinical trial. JAMA 2013 Sep 25;310(12):1240-1247. [CrossRef] [Medline]
- Elleri D, Dunger DB, Hovorka R. Closed-loop insulin delivery for treatment of type 1 diabetes. BMC Med 2011 Nov 09;9:120 [FREE Full text] [CrossRef] [Medline]
- Ming W, Mackillop LH, Farmer AJ, Loerup L, Bartlett K, Levy JC, et al. Telemedicine technologies for diabetes in pregnancy: a systematic review and meta-analysis. J Med Internet Res 2016 Nov 09;18(11):e290 [FREE Full text] [CrossRef] [Medline]
- Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 2009;339:b2535 [FREE Full text] [Medline]
- Armijo-Olivo S, Stiles CR, Hagen NA, Biondo PD, Cummings GG. Assessment of study quality for systematic reviews: a comparison of the Cochrane Collaboration Risk of Bias Tool and the Effective Public Health Practice Project Quality Assessment Tool: methodological research. J Eval Clin Pract 2012 Feb;18(1):12-18. [CrossRef] [Medline]
- Cordua S, Secher AL, Ringholm L, Damm P, Mathiesen ER. Real-time continuous glucose monitoring during labour and delivery in women with Type 1 diabetes - observations from a randomized controlled trial. Diabet Med 2013 Nov;30(11):1374-1381. [CrossRef] [Medline]
- Feig DS, Donovan LE, Corcoy R, Murphy KE, Amiel SA, Hunt KF, CONCEPTT Collaborative Group. Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial. Lancet 2017 Nov 25;390(10110):2347-2359 [FREE Full text] [CrossRef] [Medline]
- Petrovski G, Dimitrovski C, Bogoev M, Milenkovic T, Ahmeti I, Bitovska I. Is there a difference in pregnancy and glycemic outcome in patients with type 1 diabetes on insulin pump with constant or intermittent glucose monitoring? a pilot study. Diabetes Technol Ther 2011 Nov;13(11):1109-1113. [CrossRef] [Medline]
- Cyganek K, Hebda-Szydlo A, Katra B, Skupien J, Klupa T, Janas I, et al. Glycemic control and selected pregnancy outcomes in type 1 diabetes women on continuous subcutaneous insulin infusion and multiple daily injections: the significance of pregnancy planning. Diabetes Technol Ther 2010 Jan;12(1):41-47. [CrossRef] [Medline]
- Jotic A, Milicic T, Lalic K, Lukic L, Macesic M, Stanarcic Gajovic J, et al. Evaluation of glycaemic control, glucose variability and hypoglycaemia on long-term continuous subcutaneous infusion vs. multiple daily injections: observational study in pregnancies with pre-existing type 1 diabetes. Diabetes Ther 2020 Feb 15;11(4):845-858. [CrossRef]
- Feig DS, Corcoy R, Donovan LE, Murphy KE, Barrett JFR, Sanchez JJ, CONCEPTT Collaborative Group. Pumps or multiple daily injections in pregnancy involving type 1 diabetes: a prespecified analysis of the CONCEPTT randomized trial. Diabetes Care 2018 Dec;41(12):2471-2479. [CrossRef] [Medline]
- Gutaj P, Zawiejska A, Brązert J, Wender-Ożegowska E. Association between preconceptional treatment with insulin pumps and improved metabolic status in early pregnancy in women with type 1 diabetes. Pol Arch Med Wewn 2015;125(5):329-336 [FREE Full text] [CrossRef] [Medline]
- Stewart ZA, Wilinska ME, Hartnell S, Temple RC, Rayman G, Stanley KP, et al. Closed-loop insulin delivery during pregnancy in women with type 1 diabetes. N Engl J Med 2016 Aug 18;375(7):644-654. [CrossRef] [Medline]
- Stewart ZA, Wilinska ME, Hartnell S, O'Neil LK, Rayman G, Scott EM, et al. Day-and-night closed-loop insulin delivery in a broad population of pregnant women with type 1 diabetes: a randomized controlled crossover trial. Diabetes Care 2018 Jul;41(7):1391-1399. [CrossRef] [Medline]
- Alfadhli E, Osman E, Basri T. Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes. Diabetol Metab Syndr 2016;8:48 [FREE Full text] [CrossRef] [Medline]
- Paramasivam SS, Chinna K, Singh AKK, Ratnasingam J, Ibrahim L, Lim LL, et al. Continuous glucose monitoring results in lower HbA in Malaysian women with insulin-treated gestational diabetes: a randomized controlled trial. Diabet Med 2018 Aug;35(8):1118-1129. [CrossRef] [Medline]
- Wei Q, Sun Z, Yang Y, Yu H, Ding H, Wang S. Effect of a CGMS and SMBG on maternal and neonatal outcomes in gestational diabetes mellitus: a randomized controlled trial. Sci Rep 2016;6:19920 [FREE Full text] [CrossRef] [Medline]
- Lane AS, Mlynarczyk MA, de Veciana M, Green LM, Baraki DI, Abuhamad AZ. Real-time continuous glucose monitoring in gestational diabetes: a randomized controlled trial. Am J Perinatol 2019 Jul 28;36(9):891-897. [CrossRef] [Medline]
- Guo H, Zhang Y, Li P, Zhou P, Chen LM, Li SY. Evaluating the effects of mobile health intervention on weight management, glycemic control and pregnancy outcomes in patients with gestational diabetes mellitus. J Endocrinol Invest 2019 Jun;42(6):709-714. [CrossRef] [Medline]
- Mackillop L, Hirst JE, Bartlett KJ, Birks JS, Clifton L, Farmer AJ, et al. Comparing the efficacy of a mobile phone-based blood glucose management system with standard clinic care in women with gestational diabetes: randomized controlled trial. JMIR Mhealth Uhealth 2018 Mar 20;6(3):e71 [FREE Full text] [CrossRef] [Medline]
- Yang P, Lo W, He ZL, Xiao XM. Medical nutrition treatment of women with gestational diabetes mellitus by a telemedicine system based on smartphones. J Obstet Gynaecol Res 2018 May 23;44(7):1228-1234. [CrossRef]
- Bromuri S, Puricel S, Schumann R, Krampf J, Ruiz J, Schumacher M. An expert personal health system to monitor patients affected by gestational diabetes mellitus: a feasibility study. AIS 2016 Mar 15;8(2):219-237. [CrossRef]
- Miremberg H, Ben-Ari T, Betzer T, Raphaeli H, Gasnier R, Barda G, et al. The impact of a daily smartphone-based feedback system among women with gestational diabetes on compliance, glycemic control, satisfaction, and pregnancy outcome: a randomized controlled trial. Am J Obstet Gynecol 2018 Apr;218(4):453.e1-453.e7. [CrossRef] [Medline]
- Borgen I, Småstuen MC, Jacobsen AF, Garnweidner-Holme LM, Fayyad S, Noll J, et al. Effect of the Pregnant+ smartphone application in women with gestational diabetes mellitus: a randomised controlled trial in Norway. BMJ Open 2019 Nov 11;9(11):e030884 [FREE Full text] [CrossRef] [Medline]
- Kernaghan D, Farrell T, Hammond P, Owen P. Fetal growth in women managed with insulin pump therapy compared to conventional insulin. Eur J Obstet Gynecol Reprod Biol 2008 Mar;137(1):47-49. [CrossRef] [Medline]
- Murphy HR, Rayman G, Lewis K, Kelly S, Johal B, Duffield K, et al. Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial. BMJ 2008 Sep 25;337:a1680 [FREE Full text] [CrossRef] [Medline]
- Secher AL, Ringholm L, Andersen HU, Damm P, Mathiesen ER. The effect of real-time continuous glucose monitoring in pregnant women with diabetes: a randomized controlled trial. Diabetes Care 2013 Jul;36(7):1877-1883 [FREE Full text] [CrossRef] [Medline]
- Feig DS, Murphy HR. Continuous glucose monitoring in pregnant women with Type 1 diabetes: benefits for mothers, using pumps or pens, and their babies. Diabet Med 2018 Apr;35(4):430-435. [CrossRef] [Medline]
- Rys P, Ludwig-Slomczynska A, Cyganek K, Malecki M. Continuous subcutaneous insulin infusion vs multiple daily injections in pregnant women with type 1 diabetes mellitus: a systematic review and meta-analysis of randomised controlled trials and observational studies. Eur J Endocrinol 2018;178(5):545-563. [CrossRef]
- Skar JB, Garnweidner-Holme LM, Lukasse M, Terragni L. Women's experiences with using a smartphone app (the Pregnant+ app) to manage gestational diabetes mellitus in a randomised controlled trial. Midwifery 2018 Mar;58:102-108. [CrossRef] [Medline]
- Chen Q, Carbone ET. Functionality, implementation, impact, and the role of health literacy in mobile phone apps for gestational diabetes: scoping review. JMIR Diabetes 2017 Oct 04;2(2):e25 [FREE Full text] [CrossRef] [Medline]
- Yu Q, Aris I, Tan KH, Li LH. Application and utility of continuous glucose monitoring in pregnancy: a systematic review. Front Endocrinol (Lausanne) 2019 Oct 11;10:697.
Abbreviations
CG: control group |
EPHPP: Effective Public Health Practice Project |
HbA1c: hemoglobin A1c |
IG: intervention group |
MQ: moderate quality |
PRISMA: Preferred Reporting Items for Systematic Reviews and Meta-Analyses |
SQ: strong quality |
WQ: weak quality |
Edited by R Kukafka; submitted 13.10.20; peer-reviewed by R Halkes, R De Carvalho, M Lozano-Lozano; comments to author 29.11.20; revised version received 08.12.20; accepted 16.03.21; published 28.04.21
Copyright©Claudia Eberle, Maxine Loehnert, Stefanie Stichling. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 28.04.2021.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included.